摘要
检测和评估了UBF反应池爆炸后结构的现状,包括了外观情况检测、混凝土强度测试以及池壁混凝土内部缺陷检测。在保证结构安全的前提下,提出经济合理的加固处理方案。
In this paper, UBF reaction tank struture status after explosion is detected and evaluated,including the external detection,concrete strength test and the internal defect detection. In the premise of ensuring structure safety, the economical and reasonable reinforcement measures are proposed.
出处
《工业安全与环保》
北大核心
2010年第2期45-46,共2页
Industrial Safety and Environmental Protection
关键词
反应池
结构检测
内部缺陷
加固措施
reaction tank structure detection internal defect reinforement measurement