期刊文献+

凝结水精处理系统改造 被引量:8

Reformation of condensate precision processing system
下载PDF
导出
摘要 湖南大唐石门电厂凝结水精处理系统由于树脂再生分离的效果不佳,影响了凝结水精处理系统的正常使用。在尽量利用原有设备的基础上,对凝结水精处理系统进行了改造。在系统改造过程中,再生系统采用了分离效果较好的高塔分离法。改造后,凝结水精处理系统运行稳定,机组的经济性能有了很大的提高。 In Hunan Datang Shimen Power Plant,the condensate precision processing system can not operate normally due to its bad effect of resin regeneration and separation.Based on utilizing original equipments as much as possible,the condensate precision processing system had been reformed,and in the reformation,the high tower separation method with better effect had been adopted for regeneration system.After the reformation,the condensate precision processing system operates more steadily and economically.
作者 范晔晖
出处 《华电技术》 CAS 2010年第1期8-9,15,共3页 HUADIAN TECHNOLOGY
关键词 凝结水 精处理 体外再生装置 树脂再生分离 高塔分离法 系统改造 condensate precision processing outside regeneration resin regeneration and separation high tower separation method system reformation
  • 相关文献

参考文献1

  • 1刘爱忠主编..电厂化学[M].北京:中国电力出版社,2002:155.