期刊文献+

凝汽器铜管的氨基磺酸清洗及2-硫基苯骈噻唑成膜技术 被引量:4

Sulfamic acid cleaning and MBT film forming technology for copper tube of the condenser
下载PDF
导出
摘要 为了解决330MW机组凝汽器中铜管在运行中结垢腐蚀的问题,保证机组的安全经济运行,铜管进行了氨基磺酸清洗、2-硫基苯骈噻唑(简称MBT)成膜处理。清洗成膜后效果明显,凝汽器端差明显降低,真空度上升,并提出了几条工程经验,为以后同类型凝汽器的氨基磺酸清洗MBT成膜工艺提供了一些经验和教训。 In order to solve copper tube scaling corrosion of condenser problem on 330 MW operating unit and undertake uints sally and economic run,the sulfamic acid cleaning and MBT film forming technology was used in copper tube of condenser. The effect is distinct, the end-wanting obviously reduced and vacuum rate rised. Some engineering experiences are proposed. It is provided some lessons and experience for the future in the type of condenser sulfamic acid cleaning and MBT film forming.
出处 《清洗世界》 CAS 2010年第1期5-9,14,共6页 Cleaning World
关键词 凝汽器 氨基磺酸清洗 MBT成膜 经验 condenser sulfamic acid cleaning MBT film forming experiences
  • 相关文献

参考文献5

  • 1中华人民共和国经济贸易委员会.DL/T957-2005火力发电厂凝汽器化学清洗及成膜导则[S].北京:中国电力出版,2005. 被引量:1
  • 2袁卫昌,袁庆怡.氨基磺酸的清洗技术[J].清洗世界,2008,24(1):35-36. 被引量:10
  • 3秦国治,王顺.氨基磺酸清洗技术及应用实例[J].腐蚀与防护,1999,20(6):278-281. 被引量:12
  • 4发电厂热力设备化学清洗单位资质评定委员会编..火电厂热力设备化学清洗培训教材[M].北京:中国电力出版社,2007:185.
  • 5彭一胜 周柏青.氧化性杀生剂对铜缓蚀剂影响的试验研究.材料保护,2003,29(3):151-154. 被引量:1