摘要 通过对河南郑州500kV嵩山变电站的分析,从变电站的设备状况,操作模式,工作情况等几个方面着手,对比国内先进的500kV变电站运行管理模式,分析了当前情况下500kV运行模式改革的各个要素和制约瓶颈。分析表明,以嵩山变为例的传统500kV变电站,已经具备了一定的基础,但要彻底实现无人值班或少人值班,仍需进一步提高设备的可靠性和实现二次设备的远方操作。 Based on the analysis of equipment status,operating mode and working situation of 500kV SongShan substation in Zhengzhou,compared operation and management modes with advanced unattended substation,the paper analyzes some essential and restricted factors.It is pointed out that traditional 500kV substations such as Songshan have possessed certain foundations,to implement unattended and less-attended on duty, it needs to improve the reliability of equipment and realize the remote operation of secondary equipments.
出处 《河南电力》 2009年第4期9-10,15,共3页 Henan Electric Power
关键词 500KV变电站 运行管理 无人值守 集中监控 500kV substation operation and management unattended centralized monitoring