摘要 在弹药产品的质量无损检测中,小底隙的精确测量是保证产品质量的重要技术之一。为精确测量小底隙,利用CT成像的体积效应,提出一种小底隙厚度测量方法。在设定的扫描层厚下对产品进行工业CT断层扫描,使底隙完全包含在扫描层厚范围内;再将工业CT断层图像上的灰度差异转换为等效密度差异;并利用产品的材料密度及底隙物质(空气)密度来计算小底隙的厚度。实验结果表明,该方法可对0.3-2.0 mm的底隙进行测量,其最大绝对测量误差为0.03 mm,最大相对测量误差为4.8%.该方法解决了小底隙精确测量的技术难题,可满足产品无损质量检测和评价的需要。 In the non-destructive testing for some ammunition, the precise measurement for small bot- tom gap is one of the main techniques to ensure their quality. A measurement method for thickness of the small bottom gap was proposed by volume effect of the CT imaging dexterously. The position where a gap exists was scanned by industrial CT at a set scanning thickness, in which the gap is con- tained in the scanning range; the gray difference was transferred into density difference by the CT image; the thickness of the gap was calculated by densities of the material and the air in the gap. The measured result shows that the method can be applied to the gap with thickness from 0.3 mm to 2.0 ram, the maximal absolute error is less than 0. 030 mm and the relative error is less than 4.8 %. The proposed method solves the problem of measurement for the gap, and satisfies the requirement of non- destructive testing and evaluating for products.
出处 《兵工学报》 EI CAS CSCD 北大核心 2009年第12期1714-1717,共4页 Acta Armamentarii
基金 国家"863"计划项目(2006AA04Z104) 国家自然科学基金项目(60672098) 重庆市自然科学基金项目(CSTC2009BB2360)
关键词 信息处理技术 工业CT 体积效应 小底隙 测量 information processing technique industrial computed tomography volume effect small bottom gap measurement
  • 相关文献

参考文献7

二级参考文献28

  • 1[1]Right H,Marchal G,Baert AL,Hupke R.Initial Experience with Volume CT Scanning.J-Comput-Assist-Tomogr.1990,14(4):675-682. 被引量:1
  • 2[2]Wang G and Vannier MW.Stair-Step Artifacts in Three-dimensional Helical CT:An Experimental Study.Radiology,1994,191(1):79-83. 被引量:1
  • 3[3]Glover GH and Pelc NJ.Nonlinear partial volume artifacts in x-ray computed tomography.Med-Phy,1980,7(3):238-248. 被引量:1
  • 4[4]Goodenough DJ,Weaver KE,Costaridou H,Eerdmans H and Huysmans P.A new software correction approach to volume averaging artifacts in CT.Comput-Radiol,1986,10(2-3):87-98. 被引量:1
  • 5[5]Goodenough DJ,Rowberg A and Edwards W.Partial volume effects:The need to apply correction algorithm for this current limitation in spiral CT.Radiology,1995,194(p):974. 被引量:1
  • 6[6]Toki Y,Yahata M and Shibata Y.New algorithm for reducing partial artifacts in helical CT.Radiology,1993,189(p):168. 被引量:1
  • 7[7]Heuscher DJ and Vembar M.Reduced partial volume artifacts using spiral computed tomography and integrating interpolator.Med-Phy,1999,26(2):276-286. 被引量:1
  • 8[8]Kalender WA,Suss C and Polacin A.Causes of artifacts in spiral CT angiography with MIP displays.Radiology,1995,197:221. 被引量:1
  • 9[9]Hsieh J.Nonstationary noise characteristics of helical scan and its impact on image quality and artifacts.Med-Phy,1997,24(9):1375-1384. 被引量:1
  • 10[10]Hsieh J.Three-Dimensional Artifact Induced by Projection Weighting and Misalignment.IEEE Trans.Med.-Imaging,1999,18(4):364-368. 被引量:1

共引文献58

同被引文献31

  • 1GEORGE J G, RAYARAM K U. Shaped-based interpolation of multidimensional grey-level images [ J ]. IEEE Trans. Medical Imaging, 1996, 15 (6): 881-892. 被引量:1
  • 2SATHISH R, PHILIPPE T, MICHAEL U. Regularized interpolation for noise image [ J ]. IEEE Transactions on Medical Image, 2010, 29(2) : 543-558. 被引量:1
  • 3ALEXANDRA B A, TREVOR B, DENIS L. A morphology-based approach for interslice interpolation of anatomi- cal slice from volumetric images [ J ]. IEEE Transactions on Biomedical Engineering, 2008, 55 (8) : 2022-2038. 被引量:1
  • 4NG H P, ONG S H, HUANG S, et al. Salient features useful for the accurate segmentation of masticatory mus- cles from minimum slices subsets of magnetic resonance images [ J ]. Machine Vision and Applications, 2010, 21 : 449-467. 被引量:1
  • 5KIM Y J, KIM K I, CHOI J H, et al. Novel methods for 3D postoperative analysis of total knee arthroplasty using 2D-3D image registration [ J ]. Clinical Biomechanics, 2011, 26(4): 384-391. 被引量:1
  • 6NG H P, ONG S H, LIU J, et al. 3D segmentation and quantification of a masticatory muscle from MR data using patient-specific models and matching distributions [ J ]. Journal of Digital Imaging, 2009, 22 (5) : 449-462. 被引量:1
  • 7YIN Y B, ERIC A H, DING K, et al. A cubic B-spline-based hybrid registration of lung CT image for a dynamicairway geometric model with large deformation [ J ]. Physics in Medicine and Biology, 2011, 56: 203-218. 被引量:1
  • 8Starkenberg J. Ignition of solid high explosive by the rapid com- pression of an adjacent gas layer[ C ]//Proceedings of 7th Interna- tional Symposium on Detonation. White Oak, MD:Naval SurfaceWeapons Center, 1981:3 - 16. 被引量:1
  • 9United States Department of Defense. MIL-P-63252A Projectile,155 ram, HE, M795 loading, assembling and packing; military specification[ S ]. US: United States Department of Defense, 1995. 被引量:1
  • 10Wells K, Chiverton J, Partridge M, et al. Quantifying the partial volume effect in PET using Benford' s law[ J]. IEEE Transactions on Nuclear Science, 2007, 54 (5) : 1616 - 1625. 被引量:1

引证文献3

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部