期刊文献+

基于国标法的水质分析中无氨水的替代用水研究 被引量:3

Research on the Alternatives of Non-ammonia Water in Water Quality Analysis Based on the National Standard Method
下载PDF
导出
摘要 [目的]研究基于国标法测定氨氯和总氮含量时无氨水的替代用水。[方法]用氨氮快速测定仪分别对一次蒸馏水、新制二次重蒸水、无氨水等多种不同的试验用水内的氨氮含量进行了实测。[结果]新制二次重蒸馏水的氨氮含量(0.80mg/L)低,接近无氨水中实测的氨氮含量(0.70~0.90mg/L)。运用该试验用水进行实测标样和水样中氨氮和总氮的含量,结果准确,精密度良好,完全能满足实际测定的要求,具有实际应用的价值。[结论]新制二次重蒸馏水可以作为利用国标法测定氨氮和总氮含量时无氨水的替代用水。 [ Objective ] The research aimed to study the alternatives of non-ammonia water in water quality analysis basis on the national standard method. [ Method ] Ammonia ISM was used to measure the concentration of ammonia in distilled water, newly prepared double distilled water and non-ammonia water. [ Result] The results show that the ammonia concentration in newly prepared double distilled water is relatively low at 0.80 mg/L, and it is close to that of non-ammonia water at 0.70 - 0.90 mg/L. When this kind of water is used to determine the standard and sample, the accuracy and preciseness all meet the needs. This indicates that this method has its value in practical application. [ Conclusion] The newly prepared double distilled water can be used as the alternative water during the analysis of water quality basis on the national standard method.
作者 念宇 杨再福
出处 《安徽农业科学》 CAS 北大核心 2010年第1期306-306,319,共2页 Journal of Anhui Agricultural Sciences
基金 国家自然科学基金创新群体研究基金(50721006) 上海市重点学科项目(B604)
关键词 无氨水 新制双蒸水 氨氮 总氮 Non-ammonia water Newly prepared double distilled water Ammonia Total nitrogen(TN)
  • 相关文献

参考文献11

二级参考文献26

共引文献66

同被引文献15

引证文献3

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部