摘要 目的探讨18G活检抽吸针对肺部小病变及肺门病变穿刺活检的临床应用。资料与方法回顾性分析51例直径<3cm的肺部小病变和肺门病变经CT导引下活检资料,并对其穿刺活检与术后组织病理学结果及临床随访结果进行对照分析。结果51例患者成功获得足够组织标本。其中恶性病变32例,最终确诊30例,准确率93.8%(30/32);良性病变17例,最终确诊14例,准确率82.4%(14/17);未确诊2例。穿刺活检总符合率为90.2%(46/51)。并发症有:气胸4例,占7.8%(4/51),其中1例作微创性胸腔闭式引流;少量咯血2例,占3.9%(2/51);未发现致命性并发症。结论使用18G活检抽吸针对肺部小病变及肺门病变的诊断安全、可靠、准确。 Objective To evaluate the clinical applicationg of 18G biopsy needles for smaller pulmonary lesions and hilar lesions in percutaneous lung biopsy. Materials and Methods CT-guided percutaneous lung biopsy was perfomed in 51 cases of patients that had smaller pulmonary lesions of the diameter ≤3 cm and/or hilar lesions. The biopsy results and postoperative pathological diagnosis or clinical follow-up results were compared. Results 51 patients obtained enough specimens through the punctures. 32 cases of malignant lesions were eventually confirmed 30 cases, and the accuracy rate was 93.8% (30/32). 17 cases of benign lesions were confirmed 14 cases,and the accuracy rate was 82.4% (14/17). The biopsy could not indicate the accurate diagnosis in 2 cases. The total accordance rate was 90.2%. As for complica- tions,4(7.8%, 2/51 )cases suffered pnemothroax, one of them was relieved by closed mini-invasive thoracic drainage. 2 (3.9% ,2/51 )cases experienced mild hemoptysis. No fatal complications were found. Conclusion The application of 18G lung needles to smaller pulmonary lesions and hilar lesions is safe ,reliable and accurate.
出处 《临床放射学杂志》 CSCD 北大核心 2009年第12期1676-1679,共4页 Journal of Clinical Radiology
基金 河南省杰出青年计划项目(编号:084100510020)
关键词 肺活检术 体层摄影术 X线计算机 针吸 气胸 Lung biopsy Tomography X-ray computed Needle aspiration Pneumothorax
  • 相关文献

参考文献7

二级参考文献17

  • 1黄祥龙,王恭宪,沈天真,童林军,陈星荣.CT导向经胸穿刺活检108例报告[J].介入放射学杂志,1993,2(1):32-35. 被引量:6
  • 2李洪伦,郭佑民,郭晓娟,张少娟,陈敏,金晨望,牛刚.CT引导下肺内孤立性病变经皮穿刺活检并发症的分析[J].实用放射学杂志,2005,21(5):481-483. 被引量:44
  • 3Ohno Y,Hatabu H,Takenaka D,et al.CT-guided transthoracic needle aspiration biopsy of small (<or=20 mm) solitary pulmonary nodules[J].AJR,2003,180(6):1665-1669. 被引量:1
  • 4Wallace MJ,Krishnamurthy S,Broemeling LD,et al.CT-guided percutaneous fine-needle aspiration of small (<or=1 cm) pulmonary lesions[J].Radiology,2002,225(3):823-828. 被引量:1
  • 5Tsukada H,Satou T,Lwashima A,et al.Diagnostic accuracy of CT-guided automated needle biopsy of lung nodules[J].AJR,2000,175(1):239-243. 被引量:1
  • 6Li H,Boiselle PM,Shepard JO,et al.Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of lung:comparison of small and large pulmonary nodules[J].AJR,1996,167(1):105-109. 被引量:1
  • 7Westcott JL,Rao N,Colley D.Transthoracic needle biopsy of small pulmonary nodules[J].Radiology,1997,202(1):97-103. 被引量:1
  • 8Moore EH.Technical aspects of needle aspiration lung biopsy:a personal perspective[J].Radiology,1998,208(2):303-318. 被引量:1
  • 9Yankelevitz DF,Henschke CI,Koizumi J,et al.CT-guided transthoracic needle biopsy following indeterminate fiberoptic bronchoscopy in solitary pulmonary nodules[J].Clin imaging,1998,22(1):7-10. 被引量:1
  • 10Yankelevitz DF,Henschke CI,Koizumi J,et al.CT-guided transthoracic needle biopsy of small solitary pulmonary nodules[J].Clin imaging,1997,21(2):107-110. 被引量:1

共引文献40

同被引文献15

引证文献3

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部