期刊文献+

宫颈癌适形放疗实施过程精确性分析 被引量:2

A study of accuracy in conformal radiotherapy for cervical cancer
下载PDF
导出
摘要 目的分析宫颈瘤三维适形放疗时的摆位误差。方法利用双曝光照相技术拍摄验证片,将验证片与计划系统所生成的数字重建图像(DRR)对比,测量和分析验证片与DRR之间的误差。结果各方向摆位误差的分布均近似正态分布,宫颈癌患者的摆位误差主要发生在患者左右和头足方向。结论利用双曝光照相技术拍摄验证片可以有效减少摆位的误差,提高摆位的准确性。 Objective To study the set-up error during conformal radiotherapy for patients with cervical cancer. Mothods The verification films using of double-exposure photography shooting film compared with digitally reconstruted radio- graph (DRR), The deviation of set-up for patients in the left-right (X), anterior-posterior (Y) and superior-inferior (Z) di- rections were measured and analyzed. Results The distribution of set-up errors in every direction approximated a normal dis- tribution. The set-up deviations occurred mainly in x and z directions. Conclusion The using of double-exposure photography shooting film can effectively reduce the set-up error and improve the accuracy of positioning.
出处 《广州医药》 2009年第6期10-11,共2页 Guangzhou Medical Journal
关键词 宫颈癌 双曝光照相技术 摆位误差 Cervial cancer Double-exposure photography Set-up error
  • 相关文献

参考文献7

  • 1于龙珍,翟振宇,沈君姝.体部肿瘤精确放疗摆位误差分析[J].中国医学物理学杂志,2007,24(3):160-162. 被引量:36
  • 2Kinxie J J, Hanks GE, Maclean C J, et al. Patternx of care study: Hodgkin' s Disease relapse rates and adequay of portals [J] . Cancer, 1983, 52: 2223-2226. 被引量:1
  • 3胡逸民主编..肿瘤放射物理学[M].北京:原子能出版社,1999:659.
  • 4Schallenkamp JM, Herman MG, Kruse JJ, et al. Prostate position relative to pelvic bony anatomy based on imtra prostatic gold mark 2 ers and electronic portal imaging [J] . Int J Radiat Oncol Biol Phys, 2003, 63 (3): 800 -811. 被引量:1
  • 5McKenzie A, van Herk M, M ijnheer B. Margins for geomet ri2 uncertainty around organs at risk in radio therapy [J] . Radio therOnce 1, 2002, 62 (3): 299- 307. 被引量:1
  • 6Ahmad S, V lachakiM T, Teslow TN, et al. Impact of setup uncer2 tainty in the do simetry of prostate and surrounding tissues in prostate cancer patient treated with peacockIMRT [J] . Med Dosim, 2005, 30 (1): 1- 7. 被引量:1
  • 7Baiter JM, Ten-Haken RK, Lawrence TS, et al. Uncertainties in CT based radiation therapy treatment planning associated with patient breathing [ J ] . Int Radiat Oncol- Biol Phys, 1996, 36: 167-174. 被引量:1

二级参考文献8

  • 1Uematsu M,Akira S,Kazuhiko T,et al..Focal,high dose,and fractionated modified stereotactic radiationtherapy for lung carcinoma patients[J].Cancer,1998,82:1062-1070. 被引量:1
  • 2MeertensH,BijholdJ,StrackeeJ.A method of the measurement of field placement errors in digital portal images[J].Phys Med Biol,1990,35:299-323. 被引量:1
  • 3Hurkmans C W,Remeijer P,Lebesque J V,et al.Set-up verification using portal imaging; review of current clinical practice[J].Radiather Oncol,2001,58(2):105-120. 被引量:1
  • 4Hans CJ,John R.Analysis and reduction of 3D systematic and random setup deviations during the simulation and treatment of lung cancer patients with CT based external beam radiotherapy dose planning[J].Int Radiat Oncol Biol Phys,2001,49:857-868. 被引量:1
  • 5Lax I,Blomgren H,Naslund I,et al.S tereotactic radiotherapy of malignacies in the abdomen[J].Acta Oncologia,1994,33:677-703. 被引量:1
  • 6Onishi H,Kuriyama K,Komiyama T,et al.CT evaluation of patient deep inspiration self-breath-holding:how precisely can patients reproduce the tumor position in the absence of respiratory monitoring devices?Med Phys[J].2003,30(6):1183-1187. 被引量:1
  • 7Balter JM,Ten-Haken RK,Lawrence TS,et al.Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing[J].Int Radiat Oncol Biol Phys,1996,36:167-174. 被引量:1
  • 8戴建荣,胡逸民.电子射野影像系统[J].中国医学物理学杂志,1999,16(4):204-208. 被引量:26