摘要
利用自制的试验装置,进行轴对称条件下的饱和软黏土电渗固结试验,通过测量电渗过程中的电势、电流和排出的水量以及电渗结束后土体的沉降量和含水率分布,从电渗机制和能量消耗的角度研究土体的性状。结果表明:(1)土体中的电势不仅与到阴极的距离有关,而且与通电时间有关。轴对称条件下电势以折线形式分布,折点在阴极附近。(2)土体中的电场强度并不是不变的,当忽略界面电阻的影响时,它随电渗时间线性减小。(3)在电渗的后期,土体电阻率和能量消耗急剧增加,并且存在突变点。试验证明,可以通过能耗系数曲线来控制电渗时间,减少能量消耗,提高电渗效益。
A laboratory test program on electro-osmotic consolidation was conducted on saturated soft clay in the axisymmetric condition using an newly developed apparatus.Voltage,current,water discharge were observed during the test,and settlement and water content were measured after the test.Then consolidation characteristics of remolded soil were studied from the point of view of electro-osmotic mechanism and energy consumption on the basis of the measured data.The following conclusions are drawn.(1) Voltage at a certain point in the soil relies on both the distance to cathode and the working time.For axisymmetric model,electric potential is distributed in the form of a broken line,and the turning point is adjacent to cathode.(2) Electric field intensity in the soil is not constant but decreases with the working time when the interface resistance is not considered.(3) In the final stage of this test,soil resistance and the consumed energy may increase greatly close to a mutation point after a certain time.The test shows that the energy consumption curve can be used to control the electro-osmotic time and to reduce the energy consumption for a high efficiency of electro-osmosis.
出处
《岩石力学与工程学报》
EI
CAS
CSCD
北大核心
2009年第A02期4034-4039,共6页
Chinese Journal of Rock Mechanics and Engineering
基金
国家自然科学基金资助项目(50879076)
关键词
土力学
电渗
二维固结
电势分布
电场变化
能量消耗
soil mechanics
electro-osmosis
two-dimensional consolidation
electric potential distribution
electric field change
energy consumption