期刊文献+

饮用水中溴酸盐、亚氯酸盐、氯酸盐、溴离子的离子色谱测定法 被引量:8

Determination of Bromate,Chlorite,Chlorate and Bromide in Drinking Water
下载PDF
导出
摘要 本文选用DIONEX ICS-2000型离子色谱仪,进样量100μL。水样中的阴离子随氢氧根淋洗液进入阴离子交换分离系统,根据分析柱对各离子的亲和力不同进行分离。结果溴酸盐、亚氯酸盐、氯酸盐、溴离子的检出限分别为:5.0μg/L、4.0μg/L、5.0μg/L、4.4μg/L;标准偏差〈5%;样品加标回收率在87.5%-95.5%。结论该方法操作简单,分析快速,灵敏度高,重现性好,能够准确检测水中卤氧化物。 A method for the determination of the negative ion, such as bromate, chlorite, chlorate and bromide in drinking water was developed by Chemically and electrolytically suppressed DIONEX ICS -2000 ion chromatography with the injection volume of 100 μL. The detection limits for bromate, chlorite, chlorate and bromide was respectively 5. 0 μg/L,4.0μg/L,5.0 μg/ L,4. 4 μg/L. The relative standard deviation was less than 5% and the recovery was between 87. 5% -95.5%. The method established in the present paper is simple, speediness, sensitive and suitable for determination of the oxyhalides in drinking water.
出处 《环境科学与管理》 CAS 2009年第11期114-116,119,共4页 Environmental Science and Management
关键词 离子色谱 溴酸盐 亚氯酸盐 氯酸盐 溴离子 ion chromatography bromate chlorite chlorate bromide
  • 相关文献

参考文献7

  • 1刘勇建,侯小平,牟世芬.饮用水消毒副产物研究状况[J].环境污染治理技术与设备,2001,2(2):31-40. 被引量:33
  • 2Kurokawa Y. , Hayashi Y. , Maekawa A. ,et al. Carcinogeniclty of potassium bromate administered orally to F334 rats. J [ J ]. Natl. Cancer Inst. , 1983,71:965 - 972. 被引量:1
  • 3KurokawaY, MaekawaA, Takahasahi M. Toxicity and carcinogenicity of potassium bromate-a new renal carcinogen [ J ]. Environ Health Perspect, 1990,87 : 309. 被引量:1
  • 4R Michalski. Inorganic oxyhalide by - products in drinking water andion chromatographic determination methods [ J ]. Polish JEnviron Studies ,2005,14 (3) :258. 被引量:1
  • 5生活饮用水卫生标准.GB5749-2006[S].北京:中国标准出版社,2006. 被引量:3
  • 6饮用天然矿泉水.GB8537-2008[S].北京:中国标准出版社,2009. 被引量:1
  • 7曾力.离子色谱法测定饮用水中无机消毒副产物[J].分析测试学报,2004,23(2):78-80. 被引量:21

二级参考文献8

共引文献54

同被引文献59

引证文献8

二级引证文献69

相关作者