本文在灵敏度分析法的基础上,对电力系统无功补偿装置SCB进行优化配置,并在New-England39节点系统上进行了验证。结果表明这一方法是可行的,有效的,可应用于电力系统分析中。
Based on the sensitivity analysis, a method of optimal allocation of reactive power sources SCB in power system is introduced in this paper. And it has been tested in New-England 39 buses system. The results indicate that the proposed method is effective and practicable to the electric power system.