期刊文献+

基于恒定导通时间的V^2控制方法研究 被引量:8

Research of the V^2 Control Method Based on Constant on Time
下载PDF
导出
摘要 恒定导通时间控制的Buck电路瞬态响应速度快,控制电路简单,但其电压调整率差,影响了其在电压调整模块(VRM)中的应用。为了提高其电压调整率,本文首先分析了基于恒定导通时间控制的Buck电路电压调整率差的原因,提出并分析了基于恒定导通时间的V2控制,通过仿真和实验对比了这两种控制方法,结果证明了基于恒定导通时间的V2控制方法具有快速的瞬态响应,而且提高了电压调整率,与恒定导通时间控制相比更适合应用在电压调整模块中。 The dynamic response of Buck circuit with COT (Constant On-Time) control is very fast, and its control circuit is simple. But its voltage regulation is not good, which inflects its application. To improve the voltage regulation, reasons of the bad voltage regulation of buck converter with COT control method are analyzed in this paper. The V^2 control method based on constant on-time is used to improve voltage regulation. The COT control and the V^2 control method based on constant on-time are compared through simulation and experiment. The results of simulation and experiment prove that not only the dynamic response of the voltage regulation is improved a lot. Compared to V^2 control method based on constant on time is excellent, but also its COT control method, it is more fitful for VRM application.
出处 《电测与仪表》 北大核心 2009年第11期73-76,共4页 Electrical Measurement & Instrumentation
基金 西南石油大学科技基金项目(2007XJZ105 2007XJZ115)
关键词 恒定导通时间 V2控制 电压调整率 constant on-time V^2 control voltage regulation
  • 相关文献

参考文献3

二级参考文献26

  • 1Holland B. Modeling, Analysis and compensation of the current-mode converter[C], Proceedings of the International Conference on Power System Technology , 1984: 1-2. 被引量:1
  • 2Middlebrook R D. Topics in Multiple-loop Regulators and CurrentMode Programming[J]. IEEE Transactions on Power Electronics,1987, 2(2): 109-124. 被引量:1
  • 3Middlebrook R D. Modeling Current-Programmed Buck and Boost Regulators[J]. IEEE Transactions on Power Electronics, 1989, 4(1):36-52. 被引量:1
  • 4Intel Corp. VRM 9.0 DC-DC converter design guidelines[Z], Intel Corp. Order Number 249205-004. 被引量:1
  • 5Robert Mammano, Switching Power Supply Topology Voltage Mode vs. Current Mode[M], Unitrode Product & Applications Handbook,1995-96. Order Number DN-62. 被引量:1
  • 6Daniel M, Mitchell. An analytical investigation of current-injected control for constant-frequency switching regulators[J] . IEEE Transactions onPowerElectronics, 1986, 1(3): 167-174. 被引量:1
  • 7Fengyan Wang, Songrong Wu, Jianping Xu et al. Modeling and simulation ofV2 controlled switching converters[C], 2003 Interantioanl Conference on Power Electronics and Drive Systems, Nov. 2003:613-617. 被引量:1
  • 8JACKSON D K,LEEB S B,SCHULTZ A M,et al.A Comparison of multirate digital compensators for a battery charger[C]//Proc.IEEE Workshop Comput.Power Electron.Portland:IEEE Press,1996:58-65. 被引量:1
  • 9WEI G,HOROWITZ M.A low power switching power supply for self-clocked systems[C]//Proc.Int.Syrup.Low Power Electron.Design.Monterey:IEEE Press,1996:313-317. 被引量:1
  • 10PETERCHEV A V,SANDERS S R.Quantization resolution and limit cycle in digitally controlled PWM converters[J].IEEE Transactions on Power Electronics,2003,18(1):301-308. 被引量:1

共引文献29

同被引文献138

引证文献8

二级引证文献99