期刊文献+

小跨高比钢纤维高强混凝土连梁延性和耗能研究 被引量:6

Ductility and energy dissipation capacity of steel fiber reinforced high-strength concrete coupling beams of small span/depth
下载PDF
导出
摘要 基于9根小跨高比(l/h≤2.5)钢纤维高强混凝土连梁和4根高强混凝土对比连梁试验,考察了跨高比、钢纤维体积掺率和配箍率对高强混凝土连梁位移延性和耗能能力的影响.结果表明:随着跨高比、钢纤维体积掺率和配箍率的增大,连梁的位移延性和耗能性能得到明显改善.当配箍率提高到一定程度后,由于剪压区混凝土破碎引起剪切滑移坡坏,箍筋不能完全发挥作用,配箍率对连梁的延性和耗能能力的影响不再明显.而在按非抗震要求配置箍筋的高强混凝土连梁中掺入ρf=1.0%的钢纤维,可使连梁达到与按抗震要求配置箍筋的连梁相当的位移延性系数,而当ρf=1.5%时,试件发生了弯曲破坏,从根本上改变了小跨高比高强混凝土连梁破坏的脆性性质. On the basis of the experiment of 9 steel fiber reinforced high-strength concrete coupling beams of small span/depth (l/h≤2.5) and 4 control coupling beams, the effects of span/depth, steel fiber volume fraction and stirrup content on ductility and energy dissipation capacity of high-strength concrete coupling beams were investigated. The test results show that increasing span/depth, steel fiber volume fraction and stirrup content can improve the ductility and the energy dissipation capacity of coupling beams evidently. When the stirrup content goes beyond a certain value, a shear slippage failure occurs due to the crumbling and spalling of concrete in compressive-shear region of coupling beams, and the effect of stirrup content on coupling beam is not obvious. Whereas, adding ρ1 = 1.0% steel fibers to a nonseismic coupling beam can achieve an equivalent displacement ductility ratio to that of seismic designed one. And a further increase of ρf to 1.5 % can change the failure type of a coupling beam from a brittle shear failure to a ductile flexural failure essentially.
出处 《大连理工大学学报》 EI CAS CSCD 北大核心 2009年第6期884-890,共7页 Journal of Dalian University of Technology
关键词 钢纤维高强混凝土 连梁 延性 耗能 steel fiber reinforced high-strength concrete coupling beam ductility energy dissipation
  • 相关文献

参考文献4

二级参考文献22

  • 1戴瑞同,孙占国.菱形配筋剪力墙连梁的承载能力[J].工业建筑,1993,23(10):32-38. 被引量:18
  • 2T.Paulay, J. R. Binney. Diagonally reinforced coupling beams of shear walls[R]. Shear in reinforced concrete, SP-42,American Concrete Institute, Farmington Hills, 1974,579- 598. 被引量:1
  • 3New Zealand Siandard, NZS 3101: Part 1:1995,Concrete Structures Siandard, Part 1 - the Design of Concrete Structures[S].1995 被引量:1
  • 4Building Code Requirements for Structural Concrete (ACI 318- 02)and Commentary (ACI318R-02)[S].An ACI Standard, reported by ACI Committee 318, American Concrete Institute, 2002. 被引量:1
  • 5Eurpean Prestandard,Eurocode 8,Design provisions for earthquake resisance of structures[S].European Committee for Standardization,Feb.1995 被引量:1
  • 6Theodoeios P. Tassios, Marina Moretti, Antoaios Bezas. On the behaviour and ductility of reinforced concrete coupling beams shear wslls[J].ACI Structural Journal, Nov. - Dec. 1995,711 - 720. 被引量:1
  • 7Luciano Galano, Andrea Vignoli. Seismic Beheviour of short coupling beams with different reinforcement Layouts[J].ACI Stuctural Journal, Nov. - Dec. 2000:876- 885. 被引量:1
  • 8储良成,1990年 被引量:1
  • 9李爱群,1990年 被引量:1
  • 10莫庸,1989年 被引量:1

共引文献70

同被引文献50

引证文献6

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部