期刊文献+

地震作用下方钢管混凝土板柱结构抗侧刚度的分析研究

Study on the Lateral Stiffness for Square Concrete-filled Steel Tubular Column-Slab Structures under EarthquakeAction
下载PDF
导出
摘要 本文针对地震作用下普通钢筋混凝土板柱结构抗侧刚度差的问题,运用ANSYS有限元分析软件建立了9柱4区格的方钢管混凝土板柱计算模型,分析影响方钢管板柱结构抗侧刚度的主要因素。且在相同的柱网尺寸和荷载作用下,对比分析了方钢管板柱结构和普通钢筋混凝土板柱结构的抗侧刚度,说明方钢管板柱结构是一种值得推广应用的结构形式。 Ordinary reinforced concrete column-Slab Structures under earthquake action, the lateral stiffness is poor. In this paper, The calculating models of four floor-slabs, the nine top columns and the nine bottom columns are established in order to research the frame dimensions which affect the lateral stiffness of Square Concrete-filled Steel Tubular Column-Slab Structures. And the columns in the same network size and load, the comparative analysis of square concrete-filled steel tubular column-slab structures and the general structure of reinforced concrete slab-column lateral stiffness, indicating Square Concrete-filled Steel Tubular Column-Slab Structures is a structure worthy of application.
出处 《中国西部科技》 2009年第32期8-10,共3页 Science and Technology of West China
关键词 方钢管混凝土板柱结构 抗侧刚度 计算模型 Square concrete-filled steel tubular column-slab structures The lateral stiffness Calculating model
  • 相关文献

参考文献3

二级参考文献7

  • 1袁明武.SAP84微机结构分析通用程序[M].北京大学力学系,1992.. 被引量:12
  • 2-.GBJ10-89混凝土结构设计规范[M].北京:中国建筑工业出版社,1989.. 被引量:2
  • 3AH尼尔逊 G温特尔.混凝土结构设计[M].北京:中国建筑工业出版社,1994.. 被引量:3
  • 4尼尔逊 A H,混凝土结构设计,1994年 被引量:1
  • 5Shyh Jiann Hwang,An experimental study of flat-plate and lateral loads,1993年 被引量:1
  • 6袁明式,SAP84微机结构分析通用程序,1992年 被引量:1
  • 7GBJ10-89混凝土结构设计规范,1989年 被引量:1

共引文献36