介绍了汽车停车场有害物的种类及危害,给出了排风量与送风量的计算方法,探讨了地下停车场的通风设计要点,分析了复合系统设计中应注意的问题,以积累地下停车场的通风设计经验。
It introduces types and damage of the detrimental material in the car parking lot, provides calculation method of the exhaust air rate and supply air rate, discusses the ventilation design point of the underground parking lot, and analyzes attention problems in the comprehensive system design, so as to accumulate ventilation design experiences of the underground parking lot.