期刊文献+

早产儿应用经外周静脉置入中心静脉导管非正常拔管的原因 被引量:7

Causes of non-elective removal of percutaneously inserted central venous catheters in premature infants
原文传递
导出
摘要 目的分析早产儿经外周静脉置入中心静脉导管(PICC)术后非正常拔管的原因。方法回顾性分析了104例应用PICC导管早产儿的临床资料,对其非正常拔管原因进行分析。结果104例早产儿中,93例(89.4%)为正常拔管,11例(10.6%)为非正常拔管。非正常拔管组患儿PICC管尖端位于锁骨下静脉比例明显高于正常拔管组患儿(x2=24.931,P=0.000)。非正常拔管组患儿的平均置管长度为(8.4±2.2)cm,明显低于正常拔管组的(10.2±1.6)em(t=3.391,P=0.001)。结论导管尖端未达到腔静脉可能是导致PICC非正常拔管的主要原因。 Objective To analyze the causes of non-elective removal of percutaneously inserted central venous catheters (PICC) in premature infants. Methods We retrospectively collected the clinical data of 104 premature infants and analyzed the causes of non-elective removal of PICC. Results PICC was removed when the treatment was finished ( n = 93, elective removal group) or due to complications ( n = 7, non-elective removal group). In non-elective removal group, the percentage of catheter tip located in the subclavian jugular was signifi- candy higher in non-elective removal group than in the elective removal group (X2 = 24. 931, P = 0. 000). The length of inserted catheter was (8.4 ±2.2) cm in the non-elective removal group and ( ( 10. 2 ± 1.6) cm in the elective removal group ( t = 3. 391, P = 0. 001 ). Conclusion The main cause of non-elective removal of cathe- ters in premature infants may be that catheter tip fails to reach the vena cava.
出处 《中华临床营养杂志》 CAS 2009年第2期117-119,共3页 Chinese Journal of Clinical Nutrition
关键词 早产儿 经外周静脉置入中心静脉导管 拔管 Premature infants Peripherally inserted central catheter Catheter removal