摘要
采用水解酸化-内循环反应器-循环活性污泥处理系统-气浮工艺处理盐酸林可霉素生产素废水,工程实际运行结果表明,系统处理效率高、维护管理方便;处理出水水质稳定,COD=180mg·L-1,BOD5=43mg·L-1,ρ(SS)=64mg·L-1,ρ(NH3-N)=43mg·L-1,pH=7.3,达到GB21903-2008要求。
Wastewater from antibiotics production was treated with the process of hydrolytic acidation-IC-CASS-air flotation. The project results of the actual operation showed that: the system was high efficiency and easily manageable; the effluent quality was stable:COD=180 mg·L^-1, BOD5=43 mg·L^-1 ρ(SS)=64 mg·L^-1,ρ(NH3-N)=43 mg·L^-1, pH=7.3. The effluent quality reached the standards of GB 21903- 2008.
出处
《水处理技术》
CAS
CSCD
北大核心
2009年第10期118-120,共3页
Technology of Water Treatment