期刊文献+

CT引导下经皮肺肿物穿刺活检安全准确性分析 被引量:3

Analysis of Diagnostic Accuracy and Safety of CT-guided Percutaneous Transthoracic Lung Biopsy for Pulmonary Lesions
下载PDF
导出
摘要 目的观察在CT引导下经皮肺穿刺活检的安全性及诊断准确性。方法对29例肺部肿物患者在CT引导下行穿刺活检,将所取组织标本放入福尔马林中送检,另外将针槽中残余物涂片,95%酒精固定,送细胞学检查。结果29例病例穿刺均获成功,一次穿刺到肿块部位成功率为93.10%(27/29),二次穿刺均成功。穿刺后组织病检为肺部恶性肿瘤86.20%(25/29)、隐球菌病6.89%(2/29)、肺结核3.44%(1/29),无明确诊断,术后诊断为肺鳞癌并坏死1例3.44%(1/29),肺穿刺确诊率96.55%(28/29)。5例出现气胸,程度较轻,自行吸收,2例咯血,给予对症处理后好转。无其他并发症。结论CT引导下经皮肺肿物穿刺活检安全可靠,诊断准确率高,并发症少。 Objective To evaluate the diagnostic accuracy and safety of CT-guided percutaneous transthoracic lung biopsy for pulmonary lesions. Methods Total of 29 lung lesions were pathologically biopsy diagnosed through CT-guided fine needle aspiration. The tissues, which were immobilized by formalin, were diagnosed through pathologically biopsy. In addition, the relicts of needle slot, which were immobilized by 95% alcohol, were diagnosed through cytological examine. Results All 29 lung lesions were successfully biopsied. 27 of all 29 lung lesions were successfully biopsied at first time. Only 2 cases were successfully biopsied at second time. There were 25 cases were lung cancer, 2 cases were pulmonary cryptococcosis and 1 case was TB (pulmonary tuberculosis). 1 case was diagnosed lung squamous cell cancer combining necrosis after the surgery. The diagnostic accuracy was 96.55%. 5 cases had gently pneumothorax and 2 cases had gently hemoptysis after the biopsy. Conclusion CT-guided percutaneous transthoracic lung biopsy has a high diagnostic accuracy, safe and little combining syndrome.
出处 《中国医药指南》 2009年第18期10-11,共2页 Guide of China Medicine
关键词 穿刺活检 CT引导 Lung Needled biopsy CT-guided
  • 相关文献

参考文献4

二级参考文献14

  • 1Larscheid RC,Thorpe PE, Scott WJ, et al. Percutaneous transthoracic needle aspiration biopsy: a comprehensive review of its current role in the diagnosis and treatment of lung tumors [ J ]. Chest,1998,114( 3 ) :704-709. 被引量:1
  • 2Zakowski MF. Fine needle aspiration cytology of tumor: diagnostic accuracy and potential pitfalls [ J ]. Cancer Invest, 1994,12 ( 5 ):505-510. 被引量:1
  • 3Laurent F, Latrabe V, Vergier B, et al. Percutaneous CT guided biopsy of the lung: comparison between aspiration and automated cutting needles using a coaxial technical aspiration and automated cutting[ J]. Cardiovasc Intervent Radiol, 2000,23(2) :266-272.?A?A 被引量:1
  • 4Dennie CJ,Matzinger FR,Marriner JR,et al.Transthoracic needle biopsy of the lung: results of early discharge in 506 outpatients.Radiology,2001 ,219:247-251. 被引量:1
  • 5Swischuk JL,Castaneda F,Patel JC,et al.Percutaneous transthoracic needl e biopsy of the lung: review of 612 lesions.J Vasc Interv Radiol,1998 ,9:347 -352. 被引量:1
  • 6Charig MJ,Phillips AJ.CT-guided cutting needle biopsy of lung lesions -s afety and efficacy of an out-patient service.Clin Radiol,2000,55:964-969 . 被引量:1
  • 7Laurent F,Latrabe V,Vergier B,et al.CT-guided transthoracic needle bio ps y of pulmonary nodules smaller than 20 mm: results with an automated 20-gauge c oaxial cutting needle.Clin Radiol ,2000 ,55:281-287. 被引量:1
  • 8Yankelevitz DF,Vazquez M,Henschke CI.Special techniques in transthoracic needle biopsy of pulmonary nodules.Radiol Clin North Am,2000 ,38:267-279. 被引量:1
  • 9Klein JS,Zarka MA.Transthoracic needle biopsy.Radiol Clin North Am,2000,38:235-266. 被引量:1
  • 10Rozenblit AM,Tuvia J,Rozenblit GN,et al.CT-guided transthoracic needle b io psy using an ipsilateral dependent position.AJR Am J Roentgenol,2000,174:17 59-1764 . 被引量:1

共引文献173