期刊文献+

Geometry Sensitivity of Magnetohydrodynamic Duct Flow and Some Abnormal Phenomena

Geometry Sensitivity of Magnetohydrodynamic Duct Flow and Some Abnormal Phenomena
下载PDF
导出
摘要 Geometry sensitivity of magnetohydrodynamics (MHD) duct flow and some ab- normal phenomena deviating from the classical MHD laws were measured in an experimental investigation of the MHD effect of the flow channel inserter (FCI) duct flow. The results showed that the velocity distribution deviated from the M-type profile on the centre-plane of the cross section of the duct with small slots (in short "S-duct"). The electric potential difference in the duct wall was much lower than that given by the classical electromagnetic laws. The MHD pres- sure drop was much higher than that from the classical magneto-hydrodynamics theory. These results may help us find some new methods to reduce the MHD pressure drop, or explore other potential applications such as flow structure control. Geometry sensitivity of magnetohydrodynamics (MHD) duct flow and some ab- normal phenomena deviating from the classical MHD laws were measured in an experimental investigation of the MHD effect of the flow channel inserter (FCI) duct flow. The results showed that the velocity distribution deviated from the M-type profile on the centre-plane of the cross section of the duct with small slots (in short "S-duct"). The electric potential difference in the duct wall was much lower than that given by the classical electromagnetic laws. The MHD pres- sure drop was much higher than that from the classical magneto-hydrodynamics theory. These results may help us find some new methods to reduce the MHD pressure drop, or explore other potential applications such as flow structure control.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2009年第4期499-503,共5页 等离子体科学和技术(英文版)
基金 supported by National Natural Science Foundation of China (No.10775042)
关键词 MHD effect geometry sensitivity S-duct MHD effect, geometry sensitivity, S-duct
  • 相关文献

参考文献11

  • 1Hunt J C, Holroryd R J. 1977, Application of Lab. And theoretical MHD duct flow studies in fusion reactor technology. Dept. of engineering, Univ. of Cambridge, Cambridge, UK,CLM-R169 SBN85311 0530. 被引量:1
  • 2Smith D L. 1985, Fusion Technology, 8:10. 被引量:1
  • 3Reimann J, Barleon L, Bucenieks I, et al. 1995, Fusion Engineering and Design, 27:593. 被引量:1
  • 4Tillack M S, Wang X R, Engineering and Design, Pulsifer J et al. 2003, Fusion 65:215. 被引量:1
  • 5Xu Zengyu, Pan Chuanjie, Wei Wenhao, et al. 1999, Fusion Technology, 36:47. 被引量:1
  • 6Norajitra P, Buhler L, Fisher U, et al. 2002, Fusion Engineering and Design, 61/62:449. 被引量:1
  • 7Wong C P C, Chernov V, Kimura A, et al. 2007, Journal of Nuclear Materials, 367:1287. 被引量:1
  • 8Smolentsev S, Morley N, Abdou M. 2005, Fusion Engineering and Design, 73:83. 被引量:1
  • 9Akihiko S, Akihiro S, Takayuki T, et al. 2006, Fusion Engineering and Design, 81:579. 被引量:1
  • 10Xu Zengyu, Pan Chuanjie, Jiang Weihong, et al. 1998, Fusion Engineering and Design, 39/40:793. 被引量:1