由热力性能考核试验数据,分析了135 MW机组改造后的经济指标和存在的差距,以及导致经济指标差的结构因素,通过结构因素完善前后两次试验数据的比较,分析了结构因素对试验结果的影响。
Based on performance test data of 135 MW unit, it has been analyzed that the economical characteristic and difference with the design data, and the structure factor causing poor characteristic. By comparing two groups of test data before and after perfect, the effect of structure factor on test result has been analyzed.
出处
《山东电力技术》
2009年第5期1-3,35,共4页
Shandong Electric Power
关键词
135
MW机组
节能改造
性能试验
热力特性
结构因素
135MW unit
energy saving retrofit
performance test
thermal performance
structure factor