期刊文献+

多层螺旋CT仿真血管内窥镜对肺静脉孔的形态学评价 被引量:5

Morphologic evaluation of the pulmonary vein ostia on multislice spiral CT virtual intravascular endoscopy
原文传递
导出
摘要 目的:探讨多层螺旋CT对肺静脉孔径线及静脉鞍厚度的测量方法,分析肺静脉与左房连接变异的类型。方法:收集103例影像资料,在血管内窥镜(VIE)图像上观察肺静脉开口情况,测量长短径及静脉鞍厚度,计算肺静脉孔指数,测量左房体积。结果:标准4支肺静脉81例(78.6%),上肺静脉孔>下肺静脉孔,右上肺静脉孔>左上肺静脉孔,右下肺静脉孔>左下肺静脉孔;右肺静脉孔指数>左肺静脉孔,右下肺静脉孔指数>右上肺静脉孔,左上、下肺静脉孔指数差异无统计学意义(P>0.05);2侧静脉鞍厚度差异无统计学意义(P>0.05);男性肺静脉孔较女性大,男女性肺静脉孔指数和静脉鞍厚度差异无统计学意义(P>0.05;P>0.05)。左上肺静脉孔短径、右上肺静脉孔指数在≥70岁组与50~59岁组间,差异有统计学意义(P<0.05;P<0.05)。肺静脉孔径与左房体积有一定正相关性(P<0.05)。结论:多层螺旋CT仿真血管内窥镜能直接对肺静脉孔进行形态学观察,明确肺静脉开口有无变异,并能对肺静脉孔及静脉鞍进行测量,提供解剖信息。 Objective:To discuss a method to measure the caliber of pulmonary vein (PV) ostia and the thickness venous saddle,and to analyse the variations in pulmonary venous drainage to the left atrium. Method:The data of one hundred and three patients were collected in this study.PV ostia and venous saddle were observed and measured in VIE images.Veins ostial index(VOI) were calculated and the left atrium volume were measured. Result:Most patients (n=81,78.6%) had four standard PVs.The caliber of the superior PV ostia was larger than that of the inferior PV ostia.The right superior PV ostia was larger than the left superior PV ostia and the right inferior PV ostia was larger than the left inferior PV ostia.The VOI of the right was larger than that of the left.The VOI of the right inferior PV ostia was larger than that of the right superior PV ostia. The VOI of the left superior and inferior PV ostia were similar (P〉0.05).The thickness of bilateral veinous saddles were similar (P〉0.05).The caliber of PV ostia in men was larger than that in women.The VOI and thickness of venous saddle between mem and women were similar(P〉0.05;P〉0.05).The short caliber of the left superior PV ostia were different in age groups between 70 or beyond and 50 to 59,as well as the VOI of the right superior PV ostia(P〈0.05;P〈0.05).The caliber of PV ostia had some positive relativity with the left atrium volume(P〈0.05).Conclusion:Multislice spiral CT virtual intravascular endoscopy could immediately observe the PV ostia ,confirm the variations in PV ostia and measure the caliber and venous saddle,so as to provide valuable information on anatomy.
出处 《临床心血管病杂志》 CAS CSCD 北大核心 2009年第9期693-697,共5页 Journal of Clinical Cardiology
关键词 心房颤动 肺静脉 体层摄影术 X线计算机 导管消融术 atrial fibrillation pulmonary veins tomography x-ray computed catheter ablation
  • 相关文献

参考文献13

  • 1SAITO T, WAKI K, BECKER A E. Left atrial myocardial extension onto pulmonary veins in humans : anatomic observations relevant for atrial arrhythmias [J].J Cardiovasc Electrophysiol, 2000,11 : 888-- 894. 被引量:1
  • 2LIN W S,PRAKASH V S,TAI C T,et al. Pulmonary vein morphology in patients with paroxysmal atrial fibrillation initiated by ectopic beats originating from the pulmonary veins: implica tions for catheter ablation[J].Circulation, 2000,101:1274 -1281. 被引量:1
  • 3HUANG H,WANGX,CHUNJ,et al. A single pul monary vein as electrophysiological substrate of parox ysmal atrial fibril lation[J]. J Cardiovasc Electrophys iol, 2006, 17:1193--1201. 被引量:1
  • 4LACOMIS J M,WIGGINTON W, FUHRMAN C,et al. Multi detector row CT of the left atrium and pul monary veins before radio frequency catheter ablation for atrial fibrillation[J].Radiographics, 2003, 23 :S35 -- S48. 被引量:1
  • 5JONGBLOED M R, DIRKSEN M S, BAX J J,et al. Atrial fibrillation :multi-detector row CT of pulmona ry vein anatomy prior to radiofrequency catheter abla tion initial experience[J]. Radiology, 2005,234 : 702 - 709. 被引量:1
  • 6TSAO H M,WU M H,YU W C,et al. Role of right middle pulmonary vein in patients with paroxysmal atrial fibrillation[J].J Cardiovasc lectrophysiol, 2001, 12:1353--1357. 被引量:1
  • 7王如兴,刘旭.肺静脉前庭与心房颤动的发生和维持[J].临床心血管病杂志,2007,23(10):723-724. 被引量:3
  • 8PAPPONE C,ROSANIO S, ORETO G, et al. Circum ferential radi-ofrequency ablation of pulmonary vein ostia: a new anatomic approach for curing atrial fibril lation[J]. Circulation, 2000,102 : 2619-- 2628. 被引量:1
  • 9郝蓬,董建增,刘兴鹏,龙德勇,方冬平,喻荣辉,汤日波,胡福丽,马长生.选择性上肺静脉造影显示下肺静脉开口位置的研究[J].中国心脏起搏与心电生理杂志,2007,21(3):227-229. 被引量:11
  • 10WITTKAMPF F H, VONKEN E J, DERKSEN R, et al. Pulmonary vein ostium geometry analysis by magnetic resonance angiography [J]. Circulation, 2003, 107:21-23. 被引量:1

二级参考文献61

  • 1董建增,马长生,刘兴鹏,龙德勇,王京,刘小青.三维标测系统和单环状标测导管指示下环肺静脉线性消融电学隔离肺静脉方法学评价[J].中华心律失常学杂志,2005,9(2):105-109. 被引量:40
  • 2Vining DJ, Shifrin RY, Haponik EF, et al. Virtual bronchoscopy (abstr). Radiology, 1994,193(p) : 261. 被引量:1
  • 3Rubin GD. Beaulieu CF, Argiro V,et al. Perspective volume rendering of CT and MR images: applications for endoscopic imaging. Radiology, 1996, 199(2) : 321-330. 被引量:1
  • 4Nakasato T, Sasaki M, Ehara S, et al. Virtual CT endoscopy of ossicles in the middle ear. Clin Imaging, 2001, 25(3) : 171-178. 被引量:1
  • 5Klingebiel R, Bauknecht HC, Kaschke O, et al. Virtual endoscopy of the tympanic cavity based on high- resolution multislice computed tomographic data. Otol Neurotol, 2001,22(6) : 803-810. 被引量:1
  • 6Triglia JM, Nazarian B, Sudre- Levillain I, et al. Virtual laryngotracheal endoscopy based on geometric surface modeling using spiral computed tomography data. Ann Otol Rhinol Laryngol, 2002, 111(1) :36-43. 被引量:1
  • 7Summers RM, Aggarwal NR, Sneller MC, et al. Virtual bronchoscopy of the central airways in patients with Wegener' s granulomatosis. Chest, 2002, 121(1) :242-250. 被引量:1
  • 8Passopoulos P, Raptopoulos V, Chuttan R, et al. Development of virtual CT cholangio-pancreaticoscopy. Radiology,1998, 209( 2):570-574. 被引量:1
  • 9Fielding JR, Hoyte LX, Okon SA, et al. Tumor detection by virtual cystoscopy with color mapping of bladder wall thickness.J Urol,2002,167(2 Pt 1):559-562. 被引量:1
  • 10Delvecchio FC, Auge BK, Weizer AZ, et al. Computed tomography urography, three- dimensional computed tomography and virtual endoscopy. Curr Opin Urol, 2002, 12(2) : 137-142. 被引量:1