摘要
Falling film generation process in lithium bromide absorption refrigeration generation system is researched in thispaper. To describe the coupled heat and mass transfer of laminar falling film in vertical generation tube, a mathematicalmodel is developed, in which the effect of mass transfer on heat transfer is carefully evaluated. Moreover,an equation related Re number with solution volume flow was also obtained in given conditions. We carried outthe experiments with the mass fraction of the inlet solution LiBr being 49.5% and obtained an empirical correlationof heat transfer with the film Re number and heat flux in different volume flow. Specifically, when 5kW/m2<qw<25kW/m2 and Re<500 the heat transfer correlation is given as: h=14009.87qw0.0764Re-0.5391.