摘要
主要阐述了蒸发工段冷凝器出水温度控制策略。讨论了冷凝水出水温度——流量串级控制,给出了控制方框图和参数的整定,并以浙大中控SUPCON JX-300XP软件为例给出了回路的组态图。
The outlet temperature controlling tactics of condenser in evaporating stage were introduced. Flow cascade control of outlet temperature of condensated water was discussed and the controlling system's block diagram and parameters' setting were put forward. Furthermore, circuit forming configuration was provided based on JX-300XP software of SUPCON.
出处
《中华纸业》
CAS
北大核心
2009年第16期86-87,共2页
China Pulp & Paper Industry
关键词
蒸发工段
冷凝器
出水温度
真空度
串级控制
控制策略
evaporating stage
condenser
outlet temperature
vacuum
cascade controlling
controlling tactics