期刊文献+

基于双积分球和锁相放大测量的近红外多波长光学参量测量系统的研究 被引量:4

A Near Infrared Multi-wavelength Optical Properties Measurement System Based on Double-integrating-spheres and Lock-in Detection
下载PDF
导出
摘要 介绍了一种基于近红外LD光源及锁相检测技术的双积分球组织光学参量测量系统,波长范围为1300~1600nm,正弦电调制光信号,光开关切换不同波长.提出了积分球系统改进措施,测量了散射/吸收混合溶液在1310nm下的光学参量,结果显示,约化散射系数和吸收系数的测量相对偏差分别<5%和10%. A multi-wavelength optical property measurement system based on LDs in near infrared,doubleintegrating-spheres, and lock-in detection was introduced. Laser Diodes in 1 300 - 1 600 nm were sinusoidaly modulated in 30 KHz and an optical switch was adopted for wavelength selection. Based on the investigation of the factors affecting the measurement accuracy, the system was fully improved. For evaluating the system,the optical properties of intralipid-10 % solution and a mixture of intralipid /CuSO4 were measured in 1 310 nm and compared with those reported in literatures or measured with other tools. It is concluded that the system can get the accurate reduced scattering coefficient and absorption coefficient with a relative error of less than 5% and 10% ,respectively.
出处 《光子学报》 EI CAS CSCD 北大核心 2009年第7期1811-1815,共5页 Acta Photonica Sinica
基金 国家自然科学基金(60578008) 科技部"十一五"攻关项目(2006BAI03A03) 高等学校学科创新引智计划(B07014)资助
关键词 组织光学 光学参量 近红外光 双积分球 锁相测量 Tissue optics Optical properties Near infrared Double integrating spheres Lock-in measurement
  • 相关文献

参考文献1

二级参考文献15

  • 1Pickering J W, Prahl S A, Van Wieringen N,et al. Double-integrating-sphere system for measuring the optical properties of tissue. Applied Optics, 1993,32(4):399-410 被引量:1
  • 2Kienle A, Lilge L, Patterson M S, et al. Spatially resolved absolute diffuse reflectance measurements for noninvasive determination of the optical scattering and absorption coefficients of biological tissue. Applied Optics, 1996,35(13):2304~2314 被引量:1
  • 3Contini D, Martelli F,et al.Photon migration through a turbid slab described by a model based on diffusion approximation:I. Theory. Applied Optics, 1997,36(9): 4587-4599 被引量:1
  • 4Kienle A,Patterson M S.Improved solutions of the steady-state and the time-resolved diffusion equations for reflectance from a semi-infinite turbid medium.Journal of the Optical Society of America A, 1997,14(1):246~254 被引量:1
  • 5Groenhuis R A,et al. Scattering and absorption of turbid materials determined from reflection measurements:1. theory. Applied Optics, 1983,22(16):2456-2462 被引量:1
  • 6Farrell T J, Patterson M S,Wilson B C.A diffusion theory model of spatially-resolved, steady-state diffuse reflectance for the noninvasive determination of tissue optical properties in vivo. Medical Physics, 1992, 19(4):879~888 被引量:1
  • 7Haskell R C, Svaasand L O, Tsay T T, et al. Boundary conditions for the diffusion equation in radiative transfer. JOSA A, 1994,11(10):2727-2741 被引量:1
  • 8Bolin F P, Preuss L E, Taylor R C,et al. Refractive index of some mammalian tissue using a fiber optic cladding method. Applied Optics, 1989,28(12):2297-2303 被引量:1
  • 9Tearney G J, Brezinski M E, Southern J F, et al. Determination of the refractive index of highly scattering human tissue by optical coherence tomography. Optics Letters, 1995,20(21):2258-2260 被引量:1
  • 10Hielscher A H, Jacques S L, Wang L, et al.The influence of boundary conditions on the accuracy of diffusion theory in time-resolved reflectance spectroscopy of biological tissue. Physics in Medicine and Biology, 1995,40(11):1957~1975 被引量:1