两种消毒液调拌藻酸盐印模材对印模尺寸稳定性的影响 被引量:6

In Vitro Investigation of Dimensional Stability of Alginate Impression Mixed with two Sorts of Disinfectants
下载PDF
导出
摘要 目的:评价用两种消毒液直接调拌藻酸盐印模材对印模尺寸稳定性有无影响。方法:分别用蒸馏水、0.2%的次氯酸钠和0.1%的洗必泰调拌藻酸盐印模材,对同一试件制取20组印模,以蒸馏水调拌者为对照组。用超硬石膏灌模,40min脱模静置24h测量模型三维标志点的长度再进行统计学分析。结果:试验组和对照组模型三维标志点长度无显著性差异。结论:0.2%的次氯酸钠或0.1%的洗必泰直接调拌藻酸盐印模材进行印模消毒不影响印模尺寸稳定性,可用于口腔科印模消毒。 Objective: To evaluate the dimensional stability of alginate impression made from alginate material mixed with two sorts of disinfectants. Methods: 20 groups of alginate material impression of the custom model were made, mixed with distilled water, 0.2% NaClo and 0. ,1% hibitane, respectively. The distilled water group acted as the control The dental stone was poured into the impressions and the casts were got 40 minutes later. The dimensional signs of the casts were measured after 24 hours and the data were analyzed statistically. Results: The measurements between test group and control group showed no statistical difference. Conclusion: The disinfection method of mixing alginate material with 0.2% NaClo or 0.1% hibitane directly doesnl influence the accuracy of the impression.
出处 《口腔医学研究》 CAS CSCD 北大核心 2009年第3期274-275,共2页 Journal of Oral Science Research
关键词 调拌法 藻酸盐印模 消毒 尺寸稳定性 Mixed method Alginate impression Disinfection Dimensional stability
  • 相关文献

参考文献6

二级参考文献17

  • 1Powell GL,Runnells RD.The presence and identification of organisms transmitted to dental laboratory[J].J Prosthet Dent,1990,64:235-237 被引量:1
  • 2Leung RH,Schonfeld SE.Gysum casts as a potential source of microbial cross-contamination[J].J Prosthet Dent,1983,49:210-211 被引量:1
  • 3Flanagan DA,Palenik CJ,Steocos J,et al.Antimicrobial activities of dental impression materials[J].Dent Mater,1998,14:399-404 被引量:1
  • 4Rice CD,Dykstra MA,Feil PH.Microbial contamination in two antimicrobial and four contral brands of alginate impression material[J].J Prosthet Dent,1992,67:535-540 被引量:1
  • 5Tobias RS,Browne RM,Wilson CA.An invitro study of the antibacterial and antifungal properties of an irreversible hydrocolloid impression material impregnated with disinfectant[J].J Prosthet Dent,1989,62:601-605 被引量:1
  • 6Federick DR, Caputo A. Comparing the accuracy removable hydrocolloid and elastomaric impression materials. J Am Dent A ssoc, 1997, 128(2)∶183-188 被引量:1
  • 7Chaffee NR.Dimensional Accuracy of improved dental stone and epoxy resin die materials PartⅡ:Complete areh form. J Prosthet Dent, 1997, 77∶235-238 被引量:1
  • 8Gien P, MeGivey Alan B. Carr. McCracken's Removable Partial Peosthodontics, 10th Edition. Mosby Publishing Co. Inc, 2000∶221 被引量:1
  • 9Richards MW, Zeiaei S, Bagby MD,et al, Working times and dimensional accuracy of the one-step putty wash impression technique. J Prosthodont, 1998, 7(4)∶250-254 被引量:1
  • 10Gordon GE, Johnson GH, Drennon DG. The effect of tray selection on the accuracy of elastameric impression materials. J Prosthet Dent,1990,63(1)∶12-18 被引量:1