摘要 目的探讨美学区域即刻种植修复的临床应用及疗效。方法14例患者美学区域新鲜拔牙创即刻植入22颗种植体并行即刻临时修复,3-6个月后制作终义齿,临床观察8-22个月。结果22颗种植体永久修复后6-12个月,X线观察种植体颈部边缘骨吸收均小于1.5 mm,种植体无松动脱落。结论严格掌握适应证,保证种植体良好的初期稳定性,行无功能的临时修复,美学区域行即刻种植修复能够获得良好的临床效果。 Objective To investigate the clinical results of immediate implant with immediate non-functional occlusion restoration in esthetic zone. Methods Fourteen cases underwent immediate implant and immediate non-functional occlusion restoration for 22 dent- al implants in esthetic zone, final restoration was performed 3-6 months later, and the follow - up time was 8-22 months. Results All of the 22 implants achieved good clinical results. The marginal bone loss of peri-implant was below 1.5mm after 6 ~ 12 months. Conclusion In esthetic zone, immediate implant with immediate non-functional occlusion restoration can get good clinical results by strictly selecting indicetions selected so that the implant primary stability is ideal.
出处 《口腔医学》 CAS 2009年第6期298-299,314,共3页 Stomatology
关键词 即刻种植 即刻修复 美学区域 immediate implant immediate restoration esthetic zone
  • 相关文献

参考文献8

  • 1Lorenzoni M,Pertl C,Zhang K,et al.Immediate loading of single-tooth implants in the anterior maxilla.Preliminary results after one year[J].Clin Oral Implants Res,2003,14(2):180-187. 被引量:1
  • 2Ericsson I,Nilson H,Lindh T,et al.Immediate functional loading of Branemark single tooth implants.An 18 months' clinical pilot follow-up study[J].Clin Oral Implants Res,2000,11(1):26-33. 被引量:1
  • 3Ericsson I,Nilson H,Lindh T,et al.Immediate occlusal loading of Branemark implants applied in various jawbone regions:a prospective,1-year clinical study[J].Clin Implant Dent Relat Res,2001,3(4):204-213. 被引量:1
  • 4Piattelli A,Paolantonio M,Corigliano M,et al.Immediate loading of titanium plasma-sprayed screw-shaped implants in man:a clinical and histological report of two cases[J].J Periodontol,1997,68 (6):591-597. 被引量:1
  • 5Viceconti M,Muccini R,Bernakiewicz M,et al.Large-sliding contact elements accurately predict levels of bone-implant micromotion relevant to osseointegration[J].J Biomech,2000,33(12):1611-1618. 被引量:1
  • 6Ivanoff CJ,Sennerby J,Johansson C,et al.Influence of implant diameter on integration of screw implants.An experimental study in rabbits[J].Int J Oral Maxillofac Surg,1997,26(2):141-148. 被引量:1
  • 7Satomi K,Akagawa Y,Nikai H,et al.Bone-implant interface structures after non tapping and tapping insertion of screw-type titanium alloy endosseous implants[J].J Prosth Dent,1988,59(3):339-342. 被引量:1
  • 8Higuchi KW,Folmer T,Kultje C.Implant survival rates in partially edentulous patients:A 3 year prospective multicenter study[J].J Oral Maxillofac Surg,1995,53(3):264-268. 被引量:1

同被引文献33

引证文献4

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部