期刊文献+

An online monitor ionization chamber used in particle therapy

An online monitor ionization chamber used in particle therapy
下载PDF
导出
摘要 The clinical trials of tumor therapy using heavy ions beam 12C are now in progress at Institute of Modern Physics in Lanzhou. In order to achieve the precise radiotherapy with the high energy 12C beam in active pencil beam scanning mode, we have developed an ionization chamber(IC) as an online monitor for beam intensity and also a dosimeter after calibration. Through the choosing of working gas and voltage, optimizing of the electrics and the read-out system, calibrating the linearity, the detector system provide us one of the simple and highly reliable way to monitoring the beam during the active pencil beam scanning treatments. The measurement results of this detector system show that it could work well under the condition of high energy 12C beam in active pencil beam scanning mode. The clinical trials of tumor therapy using heavy ions beam ^12C are now in progress at Institute of Modern Physics in Lanzhou. In order to achieve the precise radiotherapy with the high energy ^12C beam in active pencil beam scanning mode, we have developed an ionization chamber(IC) as an online monitor for beam intensity and also a dosirneter after calibration. Through the choosing of working gas and voltage, optimizing of the electrics and the read-out system, calibrating the linearity, the detector system provide us one of the simple and highly reliable way to monitoring the beam during the active pencil beam scanning treatments. The measurement results of this detector system show that it could work well under the condition of high energy ^12C beam in active pencil beam scanning mode.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2009年第3期177-180,共4页 核技术(英文)
基金 Supported by the National Nature Science Foundation of China (No. 10305015, No.10475098) the Major Program of the Chinese Academy of Science (No. O701050YZD)
关键词 肿瘤 治疗 临床 离子化 粒子 Heavy ion beam therapy, Integral ionization chamber, Irradiation dose, Absorb dose
  • 相关文献

参考文献10

  • 1Tobias C A, Anger H O, Lawrence J H. Am J Roentgenol Ther Nucl Med, 1952, 67(1):1-27. 被引量:1
  • 2Particle therapy facilities in operation (March 2009), available at http://ptcog.web.psi.ch/ptcentres.html 被引量:1
  • 3Amaldi U. Phys Med, 1998, 14: 76-84. 被引量:1
  • 4Eickhoff H, Bohne D, Debus J, et al. The proposed accelerator facility for light ion cancer therapy in Heidelberg Proc. 1999 Particle Accelerator Conf. New York, 1999: 2513-2515. 被引量:1
  • 5Carstro J R. Radiate Environ Biophys, 1995, 34: 45-48. 被引量:1
  • 6TANG Bin, HU Zhengguo, XU Zhiguo, et al. Nucl Electron Detect Technol (in Chinese), 2008, 28(4): 699-701. 被引量:1
  • 7MAO Ruishi, XIAO Guoqing, ZHAO Tiecheng, et al. High power laser and particle beams (in Chinese), 2008, 20(9): 1537-1540. 被引量:1
  • 8Lyman J T, Awschalom M, Berardo P, et al. Protocol for heavy charged-particle therapy beam dosimeter. AAPM Report No. 16, 1986: 13-15. 被引量:1
  • 9Brusasco C, Voss B, Schardt D M, et al. Nucl Instrum Methods Phys Res B, 2000, 168: 578-592. 被引量:1
  • 10IAEA, Absorbed dose determination in external veam radiotherapy, IAEA Technical reports Serial No. 398, International Atomic Energy Agency, Vienna, 2000: 57-63. 被引量:1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部