摘要 通过试板试验,研究了多次返修(次数从1-7次不等)对锅炉用钢20g焊接接头组织与性能的影响。结果表明,对20g接头焊缝进行超过3次返修以后,其焊接热影响区的常温冲击韧性ak、接头抗拉强度σb以及焊缝金属、熔合线和热影响区的硬度值HV等常规机械性能的变化仍在允许范围之内。弯曲试验表明,接头焊逢的冷弯性能亦无变坏迹象。金相组织观察显示,随着返修次数的增加,Heat-afectedzone(HAZ)的过热区组织粗化不明显。文中还就改善多次返修后的焊缝质量所应采取的措施进行了探讨。 The effects of 20 g welding joints′ structures and properties are studied through experiments on samples after they have been rewelded several times(from 1 to 7 respectively). The results show that changes of normal mechanical properties of the welding joints such as normal impact toughness ( a k )in HAZ(heat affected zone), tensile strength of the weld( σ b )and Vickers hardness(H V)in weld metal, weld junction and HAZ etc. are still within the permissible range even after they have been rewelded over three times; Bending tests give no evidence of degrading of the joints′ bent properties under normal atmospheric temperature. Metallographic observation illustrates that grains in overheated zone of HAZ don′t grow obviously as the number of times of repairing welding gradually increases. In the end, the possible measures on how to improve the quality of the weld are also discussed.
出处 《南京航空航天大学学报》 EI CAS CSCD 北大核心 1998年第3期275-282,共8页 Journal of Nanjing University of Aeronautics & Astronautics
关键词 焊接接头 补焊 组织 锅炉钢 力学性能 welding joints repairing welding properties change
  • 相关文献

参考文献5

  • 1王一力,金属焊接国家标准汇编,1990年,422页 被引量:1
  • 2团体著者,压力容器安全技术监察规程,1990年 被引量:1
  • 3劳人锅,蒸汽锅炉安全技术监察规程,1987年,68页 被引量:1
  • 4姜焕中,焊接方法及设备.电弧焊分册,1981年,196页 被引量:1
  • 5团体著者,金属学与热处理,1975年,164页 被引量:1

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部