摘要
简要介绍了CARDC高速所结合风洞试验和CFD两种手段,发展的跨声速三维非线性洞壁干扰修正方法。该方法采用Euler方程和N-S方程模拟模型的绕流场,以实测的跨声速透气壁附近的压力分布作为风洞流场的边界条件,数值求解模型的风洞流场和自由流场,由两者之差得到洞壁干扰对模型气动力的影响。通过流场可视化软件可直观方便地分析洞壁干扰对跨声速模型绕流的影响。该方法已应用于七个模型在几种不同风洞试验段中的跨声速洞壁干扰修正,结果令人满意。
This paper briefly describes a nonlinear three dimensional transonic wall interference correction method,developed in High Speed Aerodynamics Institute of CARDC by combining wind tunnel test and CFD.In this method,flow field over the model is simulated by Euler and NS equations,the measured pressure distributions near the transonic ventilated walls are used as the boundary conditions of tunnel flow field,and the differences between tunnel flow field and free flow field over the model which are numerically solved are taken as wall effects.Influences of wall interference on the structure of transonic flow field over the model can be directly and conveniently analyzed.This method has been applied to transonic wall interference correction for seven models in various test sections,and the results are satisfactory.
出处
《流体力学实验与测量》
CSCD
1998年第2期9-19,共11页
Experiments and Measurements in Fluid Mechanics
关键词
洞壁干扰
跨声速流
风洞试验
修正
数值模拟
wall interference
transonic flow
wind tunnel test correction