提出了一个快速测定金属锑中微量砷的新方法。采用氢氧化钠沉淀分离基体锑与微量砷分离,并用催化示波极谱测定,效果良好。
A method for the rapid determination of trace As in metallic antimony was developed .The antimony matrix is separated from trace As by NaOH precipitation,and trace As is determined simultaneously by catalytic oscillopol arographic method with satisfactory results.
出处
《分析试验室》
CAS
CSCD
1998年第3期78-80,共3页
Chinese Journal of Analysis Laboratory
关键词
示波极谱法
金属锑
砷
锑
分析
测定
Oscillopolarographic method
metallic antimony
arsenic