摘要 目的探讨锁定加压钢板(LCP)、带锁髓内钉和多枚克氏针应用在中老年肱骨外科颈复杂性骨折治疗中的临床疗效。方法对本院2002年10月—2007年3月手术治疗并获得1年随访的肱骨外科颈骨折58例,年龄39~65岁,NeerⅡ型骨折33例,Ⅲ~Ⅳ型骨折25例,按手术方式不同分为:LCP组36例,带锁髓内钉治疗组(A组)11例,多枚克氏针治疗组(B组)11例,各组均采用手法复位。术后就术中出血量、切口总长度、伤口延迟愈合率、8周骨折愈合率、术后肩关节外展活动度方面,将LCP组分别与A组、B组进行统计学分析,肩关节功能按Constant-Murley绝对值标准评分。结果LCP组和A组比较切口总长度、伤口延迟愈合率、8周骨折愈合率无统计学意义(P>0.05),两组术中出血量、肩关节最大外展度数有统计学意义(P<0.05)。LCP组和B组比较术中出血量、伤口延迟愈合率无统计学意义(P>0.05),两组切口总长度、8周骨折愈合率、肩关节最大外展度数有统计学意义(P<0.05)。肩关节功能Constant-Murley绝对值评分结果:治疗Ⅱ型骨折LCP组优良率90.9%,Ⅲ~Ⅳ型骨折LCP组优良率85.7%。A组优良率45.5%,B组优良率36.4%。结论治疗中老年肱骨外科颈复杂性骨折首选应用锁定加压钢板技术固定,其临床疗效优于带锁髓内钉和多枚克氏针固定技术。 Objective To analyze the clinical efftects of aged patients with complicated surgical neck fractures of humerus treated by locking compression plate (LCP) , interlocking intramedullary nail and multi-IGrscbner wire. Methods We retrospectively studied surgically treated 58 cases ( during October 2002-March 2007, in Lanzhou General Hospital) of surgical neck fractures of humerus and trailed over 1 year, age 39 - 65. Among 58 cases ,33 cases were type-Ⅱ fractures and 25 cases were type-Ⅲ Ⅳ fractures based on Neer classification; 36 cases were treated with locking compression plate (group LCP) , 11 cases were treated with inter-locking intramedullary nail ( group A) and 11 cases were treated with multi-Kirscbner wire ( group B) based on different operations. After operation, group LCP statistically compared with group A or group B in regard to intraoperative bleed volume, sum of operative incision length, delayed union rate of operative incision, fracture union rate of 8 weeks and postoperative abducens range of shoulder joint motion. All groups suffered manipulative reduction. Selecting Constant-murley System as a assessment standard to evaluate shoulder joint function. Results Between group LCP and group A, there were no significant difference in regard to sum of operative incision length, delayed union rate of operative incision and fracture union rate of 8 weeks ( P 〉 0.05 ) , there were significant difference in regard to bleed volume and abducens range of shoulder joint motion ( P 〈 0.05 ). Between group LCP and group B, there were no significant difference in regard to bleed volume and delayed union rate of operative incision ( P 〉 0.05 ), there were significant difference in regard to sum of operative incision length, fracture union rate of 8 weeks and abducens range of shoulder joint motion (P 〈 0.05 ). Accorc'ling to the standard of Constant-murley System for the shoulder joint function evaluation, rates a-bout 90.9% or 85.7% were perfect for type-Ⅱ or t
出处 《临床军医杂志》 CAS 2009年第3期417-420,共4页 Clinical Journal of Medical Officers
关键词 钉加压钢板 带锁髓内钉 克氏针 肱骨外科颈骨折 locking compression plate intramedullary nail kirschner wire surgical neck fractures of humerus
  • 相关文献

参考文献2

二级参考文献21

  • 1胡奕山,林本丹,钟志刚.锁定接骨板治疗肱骨近端骨折[J].中国矫形外科杂志,2004,12(16):1214-1216. 被引量:15
  • 2黄强,王满宜,荣国威.复杂肱骨近端骨折的手术治疗[J].中华骨科杂志,2005,25(3):159-164. 被引量:198
  • 3NEER C S. Displaced proximal humeral fractures I. Classification and evaluation[J]. J Bone Joint Surg (Am), 1970, 52: 1077- 1089. 被引量:1
  • 4LILL H, MULLER L P, HESSMANN M. Distal humerus fractures in elderly patients: results after open reduction and internal fixation[J]. Osteoporos Int, 2005,6 : S73- 79. 被引量:1
  • 5LILL H, HEPP P,ROSE T. The angle stable locking-proximal -humerus-plate for proximal humeral fractures using a small anterior- lateral - deltoid - splitting - approach - technique and first results[J]. Zentralbl Chir,2004,129(1) :43-48. 被引量:1
  • 6KORNER J,DIEDERICHS G,ARZDORF M,et al. A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates[J]. J Orthop Trauma,2004,18(5) :286-293. 被引量:1
  • 7EGOL K A,KUBIAK E N,FULKERSON E,et al. Biomechanics of locked plates and Screws[J]. J Orthop Trauma, 2004,18 (8) : 488-493. 被引量:1
  • 8Christoph S, Emanuel G, et al. First clinical results of the locking compression plate (LCP) injury [ J ]. Care Injured, 2003,34:43 - 54. 被引量:1
  • 9Edwards SL, Wilson NA, Zhang LQ, et al. Two - part surgical neck fractures of the proximal humerus. A biomechanical evaluation of two fixation techniques[ J]. J Bone Joint Surg, 2006,88:2258 -2264, 被引量:1
  • 10Cantu RV,Goval GJ. The use of locking plates in fracture care[ J ]. (Am) Acad Orthop Surg, 2006,14:183- 190. 被引量:1

共引文献68

同被引文献43

引证文献5

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部