期刊文献+

提高基于TDLAS的废气动态浓度测量系统分辨率与灵敏度的方法 被引量:4

Improving Measurement System's Sensitivity of Gas Dynamic Concentrations Based on TDLAS
下载PDF
导出
摘要 基于自平衡激光接收器和数字锁定放大器构造了TDLAS汽车尾气动态浓度测量系统。其中,自平衡激光接收器通过引入一个低频反馈回路去维持吸收信号和参考信号的自动平衡,有效地消除了背景噪音,扩大了测量范围;而数字锁定放大器采用一块DSP芯片TMS320F2812来实现相关检测算法,大大降低了系统的白噪音,提高了测量灵敏度。 A measurement system for gas dynamic concentrations based on TDLAS was constructed by using an auto-balanced photoreceiver and a digital lock-in amplifier. The photo-receiver was able to reduce the background noise and increase measurement range by using a low frequency feedback loop to maintain automatic DC balance between signal and reference arms. The digital lock-in amplifier can cancel system white noise and get higher sensitivity by using a DSP chip of TMS320F2812 to carry out the correlative detection algorithm.
出处 《仪表技术与传感器》 CSCD 北大核心 2009年第5期99-102,共4页 Instrument Technique and Sensor
基金 国家自然科学基金(60474042) 广东省自然科学基金(04020000)
关键词 微弱信号 自平衡激光接收器 数字锁定放大器 weak signal auto-balanced photoreceiver digital lock-in amplifier
  • 相关文献

参考文献10

  • 1NEMTCHINOV V, VARANASI P, ROTHMAN L S,et al. The HITRAN molecular spectroscopic database and HAWKS( HITRAN Atmospheric Workstation) :1996 Edition. J. Quant. Spectrosc. Radiat. Trannsfer, 1998,60(5) :665-710. 被引量:1
  • 2LINERUD I, KASPERSEN P, JAEGER T. Gas monitoring in the process industry using diode laser spectroscopy. Applied Physics B, 1998,67:297 - 305. 被引量:1
  • 3SUPPLEE J M, WHITTAKER E A, LENTH W. Theoretical description of frequency modulation and wavelength modulation spectroscopy. Applied Optics, 1994,33 (27) :6294 - 6302. 被引量:1
  • 4SILVER J A. Frequency-modulation spectroscopy for trace species detection:theory and comparison among experimental methods. Applied Optics,1992,31 (6) :707 -717. 被引量:1
  • 5FEHER M, MARTIN P A. Review tunable diode laser monitoring of atmospheric trace gas constituents. Spectrochimica Acta Part A, 1995, 51:1579 - 1599. 被引量:1
  • 6WANG L G, TATE D A, RIRIS H, et al. High-sensitivity frequency - modulation spectroscopy with a GaAlAs diode laser. J. Opt. Soc. Am, 1989, B 6:871 - 876. 被引量:1
  • 7ALLEN M G,CARLETON K L,DAVIS S J,et al. Ultrasensitive dualbeam absorption and gain spectroscopy:applications for near-infrared and visible diode laser sensors. Applied Optics, 1995,34 ( 18 ) : 3240 - 3249. 被引量:1
  • 8New Focus. Model 2007&2017 User' s Manual: Nirvana Auto-Balanced Photoreceivers[ EB/OL]. [2007 - 10 - 17 ]. http://www. newfocus. com/products/documents/manuals/2007_Manual_RevC. pdf 被引量:1
  • 9戴逸松著..微弱信号检测方法及仪器[M].北京:国防工业出版社,1994:319.
  • 10Texas Instruments Incorporated. TMS320C28x DSP CPU and Instruction Set Reference Guide [EB/OL]. [2007 - 11 - 4]. http ://focus. ti. com/lit/ug/spru430d/spru430d. pdf 被引量:1