摘要
结合具体工程实例,分析了现浇楼板裂缝产生的原因,从设计和施工两方面提出了混凝土楼板裂缝的预防措施,指出只要从各方面加强管理和控制,就能大幅度减少混凝土现浇楼板裂缝的可能性。
Combined with specific engineering examples, the crack formation reasons in spot-cast concrete floor-slab were analyzed. The preventive measures of concrete floor-slab crack were proposed from design and construction. It pointed out that as long as strengthened management and control in every aspect, and the possibility of spot-cast concrete floor-slab crack can be reduced wide range.
出处
《山西建筑》
2009年第17期108-109,共2页
Shanxi Architecture
关键词
砖混结构
现浇板
裂缝
预防措施
masonry-concrete structure, spot-cast concrete color-slab, crack, preventive measures