期刊文献+

同位素稀释液相色谱串联质谱法测定血清肌酐 被引量:13

Determination of serum creatinine by isotope dilution liquid chromatography tandem mass spectrometry: a candidate reference method
原文传递
导出
摘要 目的建立一种使用同位素稀释液相色谱串联质谱法(ID-LC/MS/MS)测定血清肌酐的候选参考方法。方法以[^2H3]肌酐为内标,用无水乙醇沉淀血清中的蛋白质,用氯仿纯化上清液,用液相色谱串联质谱分离测定,以包括法定量。结果血清肌酐测定的批内、批间和总变异系数的平均值分别为0.57%(范围0.52%-0.61%)、0.43%(范围0.11%~0.59%)和0.73%(范围0.62%~0.83%)。加样回收试验的回收率范围为99.09%~101.13%。分析两种参考物质SRM909b和SRM967b,测定结果与认定值的偏差小于0.4%。结论建立了ID-LC/MS/MS法测定血清肌酐的方法,方法准确、精密、简便,可望作为血清肌酐测定的参考方法。 Objective To develop a candidate reference method for the measurement of creatinine in human serum based on isotope dilution liquid chromatography tandem mass spectrometry ( ID-LC/MS/ MS). Methods An isotopically labeled internal standard [ ^2 H3 ] creatinine was added to the serum sample and equilibrated with the endogenous creatinine. The samples were treated with anhydrous ethanol to remove proteins by precipitation. After being washed with chloroform for further clean-up, the samples were analyzed by LC/MS/MS. Serum creatinine was quantified by a bracketing calibration. Results The within-run, between-run and total coefficients of variation ranged from 0. 52% to 0. 61%, 0. 11% to 0. 59% and 0. 61% to 0. 83% , and the averages were 0. 57% , 0.43% and 0. 73% , respectively. The analytical recoveries ranged from 99. 09% to 101.13% with an average of 100. 3%. The results of analyzing the certified reference material SRM 909b ( Level Ⅰ and Ⅱ ) and SRM 967b showed biases of less than 0. 4%. Conclusions An ID-LC/MS/MS method for measuring serum creatinine has been developed. The method is highly precise and accurate and may be used as a candidate reference method for serum ereatinine measurements.
出处 《中华检验医学杂志》 CAS CSCD 北大核心 2009年第5期509-514,共6页 Chinese Journal of Laboratory Medicine
基金 国家科技支撑计划资助项目(2007BA105B09) 国家高技术研究发展计划(863)资助(2006AA020909)
关键词 肌酸酐 同位素标记 色谱法 液相 串联质谱法 Creatinine Isotope labeling Chromatography,liquid Tandem mass spectrometry
  • 引文网络
  • 相关文献

参考文献12

  • 1Myers GL, Miller WG, Coresh J, et al. Recommendations for improving serum creatinine measurement: a report from the Laboratory Working Group of the National Kidney Disease Education Program. Clin Chem, 2006, 52:5-18. 被引量:1
  • 2徐静,徐国宾,童清,贾慧敏,王清涛.北京市13家医院31套血清肌酐检测系统测定结果的比对调查及分析[J].中华检验医学杂志,2007,30(11):1288-1292. 被引量:20
  • 3Stockl D, Reinauer H. Candidate reference method for determining target values for cholesterol, creatinine, uric acid, and glucose in external quality assessment and internal accuracy control. Ⅰ. Method setup. Clin Chem,1993, 39:993-1000. 被引量:1
  • 4Thienpont LM, Leenheer AP, Sttickl D. Candidate reference method for determining target values for cholesterol, creatinine, uric acid, and glucose in external quality assessment and internal accuracy control. II. Method Transfer. Clin Chem, 1993, 39 : 1001-1006. 被引量:1
  • 5Thienpont LM, Van Landuyt KG, Stokl D, et al. Candidate reference method for determining serum creatinine by isocratic HPLC: validation with isotope dilution gas chromatography-mass spectrometry and application for accuracy assessment of routine test kits. Clin Chem, 1995, 41:995-1003. 被引量:1
  • 6Siekmann L. Determination of creatinine in human serum by isotope dilution-mass pectrometry. J Clin Chem Clin Biochem,1985, 23 : 137-144. 被引量:1
  • 7Welch M J, Cohen A, Hertz HS, et al. Determination of serum creatinine by isotope dilution mass spectrometry as a candidate definitive method. Anal Chem, 1986,58 : 1681-1685. 被引量:1
  • 8Stokes P, O' Connor G. Development of a liquid chromatography- mass spectrometry method for the high-accuracy determination of creatinine in serum. J Chromatogr B Analyt Technol Biomed Life Sci, 2003, 794:125-136. 被引量:1
  • 9Paronl R, Arcellonl C, Fermo I, et al. Determination of creatinine in serum and urine by a rapid liquid-chromatographic method. Clin Chem, 1990, 36:830-836. 被引量:1
  • 10Thienpont LM, Van Landuyt KG, Stokl D, et al. Candidate reference method for determining serum ereatininc by isocratie HPLC: validation with isotope dilution gas chromatography-mass spectrometry and application for accuracy assessment of routine test kits. Clin Chem, 1995, 41:995-1003. 被引量:1

二级参考文献4

  • 1徐静,王清涛,徐国宾.几种人血清肌酐常规测定方法与反相高压液相色谱测定法的比对研究[J].中华检验医学杂志,2007,30(6):683-686. 被引量:6
  • 2Myers GL, Miller W G, Coresh J, et al. Recommendations for improving serum creatinine measurement: a report from the laboratory working group of the national kidney disease education program. Clin Chem, 2006, 52:5-18. 被引量:1
  • 3Cockcroft DW, Gault MH. Prediction of creatinine clearance from serum creatinine. Nephron, 1976, 16:31-41. 被引量:1
  • 4Levey AS, Bosch JP, Lewis JB, et al. A more accurate method to estimate glomerular filtration rate from serum creatinine: a new prediction equation. Ann Intern Med, 1999, 130:461-470. 被引量:1

共引文献19