摘要 通过试验,研究了冷凝进风温度对单元式空调机组制冷量的影响。在大中修空调机组制冷量试验过程中,当试验条件有限、冷凝进风温度偏离名义工况的35℃时,可用该结果进行机组性能评价。 Via testing,the effect of condensing inlet air temperature on the refrigerating capacity of the self contained air conditioning set is researched.In the process of testing of refrigerating capacity of air conditioning sets in overhaul or middle repair,when the testing conditions are limited,and the difference between the inlet air temperature and that of the nominal working condition reaches 35℃,the results above can be applied in the performance evaluation of the air conditioning sets.
出处 《铁道车辆》 1998年第6期39-40,共2页 Rolling Stock
关键词 单元式空调机组 冷凝进风温度 制冷量 铁路 客车 self contained air conditioning set condensing inlet air temperature refrigerating capacity test inspection and repair
  • 相关文献

参考文献3

  • 1铁道客车车顶单元式空调机组试验方法TB/T2432-93. 被引量:2
  • 2陈沛霖等编..空调与制冷技术手册[M].上海:同济大学出版社,1990:958页.
  • 3Hou Manxi.REFRIGERATION AND CONDITIONING,Chongqing:Chongqing University Press,1990. 被引量:1

共引文献1

同被引文献18

  • 1胡益雄.单元式空调机组变工况性能试验研究[J].长沙铁道学院学报,2000,18(3):52-54. 被引量:3
  • 2杭寅,刘东,黄艳,刘俊.某高层建筑空调室外机的气流模拟及优化[J].建筑热能通风空调,2006,25(3):12-16. 被引量:15
  • 3Abdollah Avara,Ehsan Daneshgar.Optimum placement of condensing units of split-type air-conditioners by numerical simulation.Energy and Buildings,2008,40:1268-1272. 被引量:1
  • 4T T Chow,Z Lin,Q W Wang.Studying thermal performance of split-type air-conditioners at building re-entrant via computer simulation∥Sixth international IBPSA Conference Kyoto.Japan,1999:1357-1363. 被引量:1
  • 5Gang Wang,Yafeng Hu,Songtao Hu.Thermal environment of outdoor units of VRV system in high-rise building∥Proceedings:Building Simulation 2007.2007:1109-1114. 被引量:1
  • 6H Xue,B Xu,J Wu,et al.Prediction of temperature rise near condensing units in the confined space of a high-rise building.Building and Environment,2007,42:2480-2487. 被引量:1
  • 7T T Chow,Z Lin,J P Liu.Effect of condensing unit layout at building re-entrant on split-type air-conditioner performance.Energy and Buildings,2002,34:237-244. 被引量:1
  • 8T T Chow,Z Lin,Q W Wang.Effect of building re-entrant shape on performance of air-cooled condensing units.Energy and Buildings,2000,32:143-152. 被引量:1
  • 9陶文铨.数值传热学.2版.西安交通大学出版社.2004. 被引量:1
  • 10魏宗舒.概率论与数理统计教程[M].北京:高等教育出版社,2002.452-471. 被引量:3