期刊文献+

亚临床皮肤刺激后三种生理参数的变化 被引量:1

Changes of three physiological parameters after subclinical skin irritation
原文传递
导出
摘要 目的探讨经表皮失水(TEWL)、皮肤电容量(CAP)、皮肤表面pH值参数在亚临床刺激性皮炎诊断中应用的可能性。方法通过1%十二烷基硫酸钠(SIS)开放性斑贴、10次胶带粘贴及0.75最小红斑量UVB照射三种不同的刺激方法,对30名健康女性受试者的前臂屈侧进行处理,共5d。每天刺激之前进行临床评估。试验第0,6,7,8天进行TEWL、CAP及皮肤表面pH值检测。结果所有受试者8天内临床评分均为0分;SLS刺激后第6,7,8天TEWL值分别为3.17±3.07(g/m^2h)、3.32±2.84(g/m^2h)、3.22±2.36(g/m^2h),较基础值0.40±1.35(g/m^2h)升高,差异均有统计学意义(均为P=0.00)。SLS刺激后第6,7,8天CAP值较基础值下降,皮肤表面pH值较基础值升高,与基础值间差异均有统计学意义(P〈0.05)。胶带粘贴后第6,7,8天TEWL值分别为2.54±1.85(g/m^2h)、2.40±2.16(g/m^2h)、2.17±1.99(g/m^2h),较基础值0.11±1.10(g/m^2h)升高,差异均有统计学意义(均为P=0.00);胶带粘贴后第8天,皮肤表面pH值较基础值升高,差异有统计学意义(P=0.00);CAP无明显变化。0.75MED UVB照射后各生物物理参数均无明显变化。结论三种生物物理参数可以被用于亚临床性刺激性接触性皮炎的检测。不同参数对不同的刺激方法检测能力不同。 Objective Toevaluate the diagnostic significance oftransepidermal water loss (TEWL), skin capacitance (CAP) and skin surface pH in subclinical irritant dermatitis. Methods Thirty healthy females took part in the 8-day study. Four areas were delineated on the flexor side of both forearms of each subject: one area received no irritation and served as the control, one was challenged by 1% sodium lauryl sulphate (SLS), one by repeated tape stripping, and one by irradiation with 0.75 MED UVB. Irritations were continuously given for 5 days. Clinical evaluation was performed everyday before irritation. TEWL, CAP and skin surface pH were measured at baseline, on day 6, 7 and 8 after the first irritation. Results Clinical score maintained at 0 for all subjects through the 8-day study. After SLS irritation, TEWL was 3.17 ± 3.07 g/m^2h on day 6, 3.32 ± 2.84 g/m^2h on day 7 and 3.22 ± 2.36 g/m^2h on day 8, and all were significantly higher than that on day 0 (0.40 ± 1.35 g/m^2, P 〈 0.01 ). Similarly, increased skin surface pH was observed on day 6, 7 and 8 after SLS irritation compared with that at baseline (all P 〈 0.05). On the contrast, CAP decreased on day 6, 7 and 8 after SLS irritation (all P 〈 0.05 ). After tape-stripping, a significant increase was observed in TEWL on day 6, 7 and 8 compared with that at baseline (2.54± 1.85 g/m^2h, 2.40± 2.16 g/m^2h and 2.17 ± 1.99 g/m^2h vs 0.11± 1.10 g/m^2h, all P 〈 0.01 ); significant increase of pH was noted only on day 8; meanwhile, there was no any significant change in CAP. UVB irradiation induced no obvious changes in any of these physiological parameters. Conclusions These three physiological parameters can be applied to the diagnosis of subclinical irritant contact dermatitis, and their diagnostic value varies with the pattern of irritation.
出处 《中华皮肤科杂志》 CAS CSCD 北大核心 2009年第5期336-338,共3页 Chinese Journal of Dermatology
关键词 皮炎 变应性接触性 皮肤刺激试验 经表皮失水 皮肤电容量 皮肤表面pH值 Dermatitis, allergic contact Skin irritancy tests Transepidermal water loss Skin capacitance Skin surface pH
  • 相关文献

参考文献7

  • 1Rycroft RJG, Menne T, Frosch PJ, et al. Textbook of Contact Dermatitis. Berlin: Springer-Verlag, 1992: 33. 被引量:1
  • 2Lee CH, Maibach HI. Study of cumulative irritant contact dermatitis in man utilizing open application on subclinically irritated skin. Contact Dermatitis, 1994, 30(5): 271-275. 被引量:1
  • 3Gloor M, Senger B, Langenauer M, et al. On the course of the irritant reaction after irritation with sodium lauryl sulphate. Skin Res Technol, 2004, 10(3): 144-148. 被引量:1
  • 4Charbonnier V, Morrison BM Jr, Paye M, et al. An open assay model to induce subclincal non-erythematous irritation. Contact Dermatitis, 2000, 42(4): 207-211. 被引量:1
  • 5Branco N, Lee I, Zhai H, et al. Long-term repetitive sodium lauryl sulfate-induced irritation of the skin: an in vivo study. Contact Dermatitis, 2005, 53 (5): 278-284. 被引量:1
  • 6Breternitz M, Flach M, Prassler J, et al. Acute barrier disruption by adhesive tapes is influenced by pressure, time and anatomical location: integrity and cohesion assessed by sequential tape stripping. A randomized, controlled study. Br J Dermatol, 2007, 156(2): 231-240. 被引量:1
  • 7Meguro S, Arai Y, Masukawa Y, Uie K, Tokimitsu I. Relationship between covalently bound ceramides and transepidermal water loss (TEWL). Arch Dermatol Res, 2000, 292(9): 463-468. 被引量:1

同被引文献5

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部