期刊文献+

UPS故障处理与运行维护探讨 被引量:5

Discussion on UPS fault handling and maintenance
下载PDF
导出
摘要 作为目前电力通信系统中的重要基础电源,UPS系统的日常维护工作并没有得到相应的重视,UPS的可靠性和使用寿命与维护水平密切相关。文章以金华电业局生产中曾经出现的几起UPS电源故障及其分析处理过程为例,对UPS在运行维护中必须重点加以关注的问题进行了探讨。提出UPS主机和蓄电池在实际运行维护中应该加强和注意的事项,具有一定的借鉴意义。 Although UPS is the key power supply in power communication system, there are some problems exists in its daily maintenance such as lacking of attentions and insufficient experience of maintenance staff. All these problems could reduce the reliability and shorten the life span of UPS. Based on UPS failure cases in Jinghua Power Supply Bureau, this paper discusses some points for attention both for UPS and battery during operation and maintenance. It has reference value for the future work.
作者 孙玲 黄兰英
机构地区 浙江金华电业局
出处 《电力系统通信》 2009年第5期69-72,共4页 Telecommunications for Electric Power System
关键词 UPS 案例 维护 探讨 UPS cases maintenance discussion
  • 相关文献

参考文献3

  • 1徐曼珍主编..新型通信电源[M].北京:人民邮电出版社,1999:264.
  • 2刘涛,魏巍,张世杰等编著..通信用UPS及逆变器[M].北京:人民邮电出版社,2008:249.
  • 3《电信技术》杂志社编..通信电源维护管理经验荟萃 2[M].北京:人民邮电出版社,2007:306.

同被引文献20

引证文献5

二级引证文献9