摘要
结合兖矿国宏化工公司2台160t/h循环流化床锅炉脱硫工艺,从脱硫效率、系统维护、运行成本等方面进行循环流化床锅炉传统干法脱硫缺陷分析,提出了系统改进措施。
Based on the application of the dry desulfurization technology in-160 t/h circulation fluidized bed boilers project in Yankuang Guohong chemical industry company,the desulfurization efficiency,system maintain ,operation cost of the FGD system were analyzed. Some countermeasures were put forward.
出处
《电力环境保护》
2009年第2期31-32,共2页
Electric Power Environmental Protection
关键词
CFB锅炉
干法脱硫
缺陷
改进
CFB boiler
dry desulfurization
disadvantage
improvement