期刊文献+

CZD-6型车载多道γ能谱测量系统 被引量:3

CAR-BORNE MULTICHANNEL GAMMA-RAY SPECTROMETRIC SYSTEM MODEL CZD-6
下载PDF
导出
摘要 CZD-6型车载多道γ能潜测量系统,以核工业北京地质研究院研制的HDY-256型便携式多道γ能谱仪为操作台,与大体积闪烁探测器构成γ能谱测量系统。每一测点的位置用GPS导航仪定位。测点的经纬度及该测点上获取的256道γ能谱数据用笔记本微机采集,可以在行进中实时显示每一测点的256道谱线。仪器安装在轻型越野车中,构成一套完整的车载多道γ能谱测量系统。该系统在石家庄航测放射性模型上通过校正后,已用于环境放射性监测。获得的大量数据表明,仪器性能稳定,工作可靠,是快速进行环境γ能谱测量的先进手段。它不仅可用于测定环境天然放射性元素浓度,而且在核事故应急处理、核污染监测中具有重要意义。 The car-borne multichannel gamma-ray spectrometric system Model CZD-6 is composed of a HDY-256 of portable multichannel gamma-ray spectrometer developed by the Beijing Research Institute of Uranium Geology and a large volume scintillation detector. The position for each measurement point is determined by the GPS instrument. Its latitude and longitude, as well as measured 256 channels of γ-spectrometric data are collected by a notebook computer, which can show the 256 channels of spectra for each point during measuring processes. The complete system can be loaded in a field car. This system has been used to environmental radioactive monitoring after calibration by airborne radiometric models in Shijiazhuang,Hebei province. A lot of data confirm that the system works stably and reliably, and is a fast and advanced approach for environmental γ-spectrometric monitoring. It can be used not only to determination of contents of natural radioactive elements in environments,but also to monitoring nuclear pollution and emergency treatment in nuclear accidents significantly.
出处 《铀矿地质》 CAS CSCD 1998年第2期112-114,共3页 Uranium Geology
关键词 γ能谱测量系统 多道γ能谱仪 环境放射性监测 Car-borne gamma-ray spectrometric system, Portable multichannel gamma-ray spectrometer, Environmental radioactive monitoring
  • 相关文献

同被引文献31

  • 1王红艳,刘森林,潘大金.车载式NaI(Tl)大晶体组的多道谱仪[J].原子能科学技术,2004,38(z1):252-254. 被引量:7
  • 2张圈世,阎春光,贾怀茂.测量环境中痕量放射性氙的能谱符合法[J].原子能科学技术,2000,34(z1):27-29. 被引量:4
  • 3韩绍阳,宋志艳,翟玉贵,柯丹,侯惠群.GR-660车载γ能谱测量系统在砂岩型铀矿勘查中的应用研究[J].铀矿地质,2007,23(4):226-233. 被引量:4
  • 4AAGEA H K, KORSBECHA U, BARGHOIZ K, et al. A new technique for processing airborne gamma ray spectrometry data for mapping low level contaminations[ J ].Applied Radiation and Isotopes, 1999,51:651 - 662. 被引量:1
  • 5STRUWE H, MACMAHON D. Feasibility study for the use of gamma and X- ray spectrometry to determine uranium contamination[J], Appl. Radiat. Isot.1996, 47: 1141-1146. 被引量:1
  • 6SKINNER G K. Gamma- ray astronomy - future prospects[J]. Adv. Space Res. 1996,15(5):161-170. 被引量:1
  • 7ROBIN P G, SAYYED E, YUANSHUI Z, et al. NaI detector neutron activation spectra for PGNAA applications [ J ].Applied Radiation and Isotopes,2000,52:483-497. 被引量:1
  • 8METWALLY W A, GARDNER R P. Stabilization of prompt gamma - ray neutron activation analysis ( PGNAA ) spectra from Nal detectors[J]. Nuclear Instruments and Methods in Physics Research A, 2004,525 : 518 - 521. 被引量:1
  • 9MOSS C E, IANAKIEV K D,PRETTYMAN TH,et al Multi-element large-volume CdZnTe detectors[J].Nuclear Instruments and Methods in Physics Research A,2001,458:455-460. 被引量:1
  • 10GUNNINK R, ARLT R. Methods for evaluating and analyzing CdTe and CdZnTe spectra [ J ]. Nuclear Instruments and Methods in Physics Research A,2001,458: 196- 205. 被引量:1

引证文献3

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部