摘要
采用Fenton氧化-混凝-SBR工艺处理糠醛废水。实验结果表明:Fenton氧化-混凝预处理糠醛废水时,在废水中硫酸亚铁和过氧化氢浓度分别为57.60mmol/L和5.22mol/L、pH为2—3的条件下,废水处理后COD可达500mg/L以下;再经SBR工艺处理,水力停留时间为18h,最终出水COD去除率可达99.67%。
The furfural wastewater was treated by Fenton reagent oxidation-coagulation-SBR process. The experimental results show that: Under the conditions of FeSO4 concentration 57.60 mmol/L, H202 concentration 5.22 mol/L and pH 2 -3, the COD of the wastewater pretreated by Fenton reagent oxidation-coagulation process is below 500 mg/L; When HRT of SBR process is 18 h, the final COD removal rate of the effluent is 99.67 %.
出处
《化工环保》
CAS
CSCD
北大核心
2009年第2期151-153,共3页
Environmental Protection of Chemical Industry
基金
吉林省教育厅"十一五"科学研究项目(吉教科合字[2007]160号)
关键词
芬顿试剂
混凝
序批式活性污泥反应器
糠醛
废水处理
Fenton reagent
coagulation
sequencing batch reactor activated sludge process
furfural
wastewater treatment