期刊文献+

SCATTERING OF A GRAZING LONGITUDINAL WAVE PULSE BY A RIBBON-TYPE CRACK—EXPERIMENTAL VERIFICATION BY THE PHOTOELASTIC METHOD 被引量:4

SCATTERING OF A GRAZING LONGITUDINAL WAVE PULSE BY A RIBBON- TYPE CRACK -EXPERIMENTAL VERIFICATION BY THE PHOTOELASTIC METHOD
原文传递
导出
摘要 By using the dynamic photoelastic method and our technique of fabricating an internal crack in solid , the scattered waves of incident grazing longitudinal ultrasonic wave pulse by a ribbon-type crack are ob-served and analyzed . In particular, the distribution of the intensity of the scattered head wave is measured quantitatively . The experimental results fairly agree with the theoretical ones given in ref. [ 1 ] . By using the dynamic photoelastic method and our technique of fabricating an internal crack in solid , the scattered waves of incident grazing longitudinal ultrasonic wave pulse by a ribbon-type crack are ob-served and analyzed . In particular, the distribution of the intensity of the scattered head wave is measured quantitatively . The experimental results fairly agree with the theoretical ones given in ref. [ 1 ] .
出处 《Chinese Journal of Acoustics》 1989年第1期15-19,共5页 声学学报(英文版)