摘要
采用场模拟方法重现河南洛阳东都商厦特大火灾过程,模拟计算烟气蔓延运动情况和温度场分布情况,分析火灾所造成人员死亡的主要原因,检验火灾现场勘察结论是否与模拟计算结论一致。
The fire of Dongdu commercial building in Luoyang City Henan province was recurred by field simulation. The smoke movement and temperature field distribution was simulated. The main cause of death was analyzed. The coherence of scene investigation result and simulation result was checked.
出处
《消防科学与技术》
CAS
北大核心
2009年第2期104-106,共3页
Fire Science and Technology
关键词
火灾重构
场模拟
烟气运动
fire reconstruct
field simulation
smoke movement