多级生化法处理抗生素制药废水的中试研究 被引量:4

Research of effect fators on the treatment of antibiotic pharmacutial wastewater by multilevel biochemistry treatment
下载PDF
导出
摘要 采用多级A/O^2生化工艺对抗生素制药废水进行了中试处理研究。结果表明缺氧池DO<0.5mg/L、好氧池DO2~3/L、温度16~30℃、有机负荷1.4~2kg COD_(Cr)/(MLSS·d)时该生化系统具有较好的去除效果,COD_(Cr)总去除率可达到80%~94%,NH_3—N总去除率达98%。 The experiment is carried out to treat antibiotic pharmacutial wastewater by using the multi- level biochemical coagulation processes.The result shows that the system has better removal efficiency about 94.4% when DO of anoxi pond is 0~0.5mg/L,aerobic pond is 2~3mg/L,water temperature is 16~20℃,and organic load on sludge is 1.4~2kgCOD_(Cr)/(MLSS·d).And after coagulation progress COD_(Cr) and NH_3-N can be decreased 80%~94% and 98% respectively.
出处 《给水排水》 CSCD 北大核心 2007年第S1期255-257,共3页 Water & Wastewater Engineering
关键词 抗生素 制药废水 多级生化处理 混凝沉淀处理 污泥处理 Aantibiotic Pharmacutial wastewater Multilevel biochemistry treatment Coagulation and sedimention process Sludge treatment
  • 相关文献

参考文献2

  • 1王凯军,秦人伟编著..发酵工业废水处理[M].北京:化学工业出版社,2000:535.
  • 2张自杰主编..排水工程 下 第4版[M].北京:中国建筑工业出版社,2000:637.