期刊文献+

凝结水泵出力不足的分析与改造 被引量:2

Condenser Pump Output Insufficient Analysis and Transformation
下载PDF
导出
摘要 凝结水泵是电厂中的重要辅助设备,德州北郊电厂自投产以来,凝结水泵在运行中曾发生诱导轮破裂、2A凝结水泵出力不足等重大设备问题,分析了凝结水泵发生问题的原因,并通过对2A凝结水泵进行改造,消除了出力不足的设备缺陷,提高了凝结水泵运行的安全性和经济性。 Condensate pump is an important auxiliary power plant equipment, power plant on the northern outskirts of Dezhou since been put into operation, condensation pumps in operation, there have been induced breakdown of the round, 2A condensate pump less effort and other major equipment problems, an- alyzes the occurrence of condensation water pump problem and through the water 2A condensation reform, efforts to eliminate the shortage of equipment defects and improve the operation of condensation water security and economy.
作者 殷淑英
出处 《煤矿机械》 北大核心 2009年第4期133-134,共2页 Coal Mine Machinery
关键词 凝结水泵 诱导轮 首级叶轮 改造 :condenser pump inducer severed head impeller transformation
  • 相关文献

参考文献2

  • 1LDTN型凝结水泵安装使用说明书[S].沈阳水泵厂,1992. 被引量:1
  • 2中国动力工程学会[K].火力发电设备技术手册:第一卷.北京:机械工业出版社.2002. 被引量:1

同被引文献6

引证文献2

二级引证文献2

相关作者