期刊文献+

基于平板探测器的锥束CT散射校正方法 被引量:8

Scatter Correction Method for Flat-Panel Detector-Based Cone Beam CT
下载PDF
导出
摘要 针对基于平板探测器的锥束CT系统固然存在的散射伪影,提出在X射线源和被检测物体之间添加一个射束衰减网格装置的散射校正方法。本文首先介绍了射束衰减网格的实验装置,然后推导了基于射束衰减网格的锥束CT散射校正方法,最后通过圆柱样品实验验证了算法的可行性。实验结果表明,研究提出的散射校正方法能有效减少基于平板探测器的锥束CT系统散射伪影,提高了重建切片图像的质量。 Aiming to the scatter artifacts for the flat-panel detector-based cone beam CT, a scatter correction method which need adding a Beam Attenuation Grid between the X-Ray source and the tested object was proposed. This study firstly described the device of the Beam Attenuation Grid, then educed the scatter correction algorithm based on the Beam Attenuation Grid. In order to improve the feasibility of this method, the cylinder phantom was experimented. The result showed that the method can effectively reduce the scatter artifacts and increase the quality of the reconstructed slice image.
出处 《CT理论与应用研究(中英文)》 2009年第1期16-22,共7页 Computerized Tomography Theory and Applications
基金 航空科学基金资助项目(2006ZD53047)
关键词 锥束CT 散射校正 康普顿散射 射束衰减网格 cone beam CT scatter correction Compton scatter beam attenuation grid
  • 相关文献

参考文献11

  • 1Halmshaw R. Industrial radiology-theory and practice[M]. London: Capman & Hall, 1995, 134-135. 被引量:1
  • 2John M B. Scatter correction algorithm for digitally acquired radiographs: Theory and result[J]. Med Phys, 1986, 13(3): 319-328. 被引量:1
  • 3李永利,桂志国,杨民,杨巧宁.X射线检测中散射模型的理论分析[J].华北工学院测试技术学报,2000,14(1):12-17. 被引量:3
  • 4Hsieh J.计算机断层成像技术原理、设计、伪影和进展[M].张朝宗,郭志平,王贤刚,等译.北京:科学出版社,2006. 被引量:1
  • 5李永利.X射线成像中散射的减小与消除[D].太原:华北工学院,2000. 被引量:1
  • 6Karin K. Two new experimental methods of calculating scatter fraction as a function of depth in scattering media: a comparison study[J]. Med phys, 1992, 19(3): 591-598. 被引量:1
  • 7Fredrick C W, ALBERT M, DWIGHT G N. A characterization of the scatter point-spread function in terms of air gaps[J]. IEEE Trans, 1988, 7(4): 168-175. 被引量:1
  • 8孙少华,高文焕,张丽,陈志强.工业CT散射校正方法的研究[J].核电子学与探测技术,2002,22(5):426-428. 被引量:3
  • 9Ning R L, Tang X Y, Conover D L. X-Ray scatter suppression algorithm for cone beam volume CT[J]. Proc SHE, 2002, 4682: 1605-7422,. 被引量:1
  • 10Cai W X, Ning R L, Conover D. Scatter correction using beam stop array algorithm for cone-beam CT breast imaging[J]. Proc SHE, 6142: 61423E-1. 被引量:1

二级参考文献10

  • 1[1]Gabor T Herman. Image reconstruction from projections: The fundamentals of computerized tomography[M].New York: Academic Press,1980. 被引量:1
  • 2[2]Wallis JW, et al. Comparison of the convergence properties of the It-W and OS-EM algorithms in SPECT[J]. IEEE Trans Nucl Sci, 1998, NS45:1317. 被引量:1
  • 3[3]Lange K, et al. Globally convergent algorithms for maximum a posteriori transmission tomography [J]. IEEE Trans Image Processing, 1995, 4(10):1430. 被引量:1
  • 4[4]Hudson HM, et al. Accelerated image reconstruction using ordered subsets of projection data[J].IEEE Trans Med Imaging, 1994,13(4):601. 被引量:1
  • 5[5]Kamphuis C, et al. Accelerated iterative transmission CT reconstruction using an ordered subsets convex algorithm[J].IEEE Trans Med Imaging, 1998,17(6):1101. 被引量:1
  • 6Boone J M,Seibert J A.An analytical model of the scattered radiation distribution in diagnostic radiology[].Medical Physics.1988 被引量:1
  • 7Joseph P M,Spital R D.The effects of scatter in X-ray computed tomography[].Medical Physics.1982 被引量:1
  • 8Msaki P,Bertil Axelsson,Dahl C M,et al.Generialized scatter correction method in SPECT using point spread distribution functions[].The Journal of Nuclear Medicine.1987 被引量:1
  • 9Smith S W,Kruger R A.A signal processing model of diagnostic X-ray scatter[].Medical Physics.1986 被引量:1
  • 10Wagner F C,Macovski Albert,Nishimura D G.A characterization of the scatter point spread function in terms of air gaps[].IEEE Transactions on Magnetics.1988 被引量:1

共引文献4