CT扫描对靶点位置精确度影响分析 被引量:1

Impact of CT scanning condition on the precision and accuracy of target position
原文传递
导出
摘要 目的研究CT扫描条件变化对利用Z形定位框架定位的WIMRT治疗系统计算坐标的影响。方法分别在定位框架横向倾斜、CT机架倾斜、定位框架轴向与CT进床方向不重合条件下全头模范围扫描,图像传输到计划系统,计算头模内不同位置的3个靶点的坐标,与标准条件下扫描计算的坐标进行比较。结果根据定位框架横向倾斜时获得的定位图像计算的靶点坐标高度、宽度值有偏差,倾斜角越大,偏差越大。且靶点宽度坐标绝对值大小会影响计算高度坐标偏差,宽度值越大,高度坐标偏差有变大的趋势;同样,靶点高度绝对值与宽度坐标计算值偏差也有以上关系。CT机架不归零、定位框架轴向与CT进床方向倾斜主要影响靶点长度坐标计算值。结论定位时必须派有资质的物理师严格按照定位的标准条件扫描。 Objective To study the effect of CT scanning condition on the target position coordinate with WIMRT radiotherapy planning system using the" Z" form localizing frame. Methods The whole Head Phantom containing three metal targets was scanned under the following conditions : localizing frame transversally tilting, CT gantry tilting and localizing frame axially tilting. Then the three target coordinates were computed respectively and compared with those under the standard condition. Results The height and width of coordinate under the localizing frame transversally tilting condition deviated from those under the standard scanning condition, which was in an angle dependent manner. On the other hand, a tendency was shown that the greater the absolute height value of the targets coordinate, the greater the width value deviation. And so was the relation between the absolute width value of the coordinate and height value deviation. If CT gantry angle was not zero degree or localizing frame axis is not in the same line with the CT bed moving direction, the calculated longititude value of the targets coordinate was mainly affected. Conclusions CT scanning must be performed strictly under the standard localizing scanning condition by a proficient physicist.
出处 《中华放射肿瘤学杂志》 CSCD 北大核心 2009年第2期142-145,共4页 Chinese Journal of Radiation Oncology
基金 四川省卫生厅科研课题(070290)(志谢研究得到CT室黄小华主任、罗开、雍娜等大力协作)
关键词 CT扫描 定位 精确度 CT scanning Localizing Precision and accuracy
  • 相关文献

参考文献17

二级参考文献55

  • 1王云彦,张庆林,江玉泉,李刚.X-刀二次等中心系统的验证[J].中国微侵袭神经外科杂志,1998,3(3):175-176. 被引量:2
  • 2吕庆文,李树祥.X刀的原理、适用范围及其优点[J].中国肿瘤,1995,4(6):16-18. 被引量:4
  • 3杨开军,刘承勇,任文德,许志新,杨雄浩.X-刀治疗的质量控制及相关物理参数的测量[J].功能性和立体定向神经外科杂志,1995,8(3):4-6. 被引量:14
  • 4王鸣鹏,吴威岚,张国桢.螺旋CT扫描成像质量分析[J].中华放射学杂志,1996,30(6):373-376. 被引量:14
  • 5Choi DR, Kim DY, Ahn YC, et al.Quantitative analysis of errors in fractionated stereotactic radiotherapy [J].Medical Dosimetry, 2001, 26(4): 315-318. 被引量:1
  • 6Choi DR, Kim DY, Ahn YC, et al.Adaptive modification of treatment planning to minimize the deleterious effects of treatment setup errors [J]. lntJ Radia Oncol Biol Phys, 1997, 38(1):197 - 206. 被引量:1
  • 7Hurkmans CW, Remeijer P, LebesqueJV, et al. Set-up verification using portal imaging; review of current clinical practice [R] . Radio Oncol, 2001, 58(2): 105 - 120. 被引量:1
  • 8Kam MK, Chau RM, Suen J, et al.Intensity-modulated radiotherapy in nasopharyngeal carcinoma: dosimetric advantage over conventional plans and feasibility of dose escalation [J] . Int J Radiat Oncol Biol Phys, 2003, 56(1):145 - 157. 被引量:1
  • 9Chang SD, Tare DJ, Goffinet DR, et al.Treatment of nasopharyngeal carcinoma:stereotactic radiosurgieal boost following fractionated radiotherapy [J] . Stereotact Funet Neurosurg, 1999, 73(1-4): 64-67. 被引量:1
  • 10Yeung 1), Paha J, Fontanesi J, et al.Systematic analysis of errors in target localization and treatment delivery insterortactic radiosurgery (SRS) [J]. Int J Radiat Oncol Biol Phys, 1993, 28(2):493 - 498. 被引量:1

共引文献186

同被引文献9

  • 1于甬华,吴玉芬,郭守芳,王仁本,李文武,李宝生.呼吸运动对周围型肺癌位置的影响及其数学模型的建立[J].中华放射肿瘤学杂志,2004,13(2):83-84. 被引量:20
  • 2Bosmans G, Van Baardwijk A, Dekker A, et al. Intra-patient variability of rumor volume and tumor motion during conventionally fractionated radiotherapy for locally advanced on-small-cell lung cancer:a prospective clinical study. Int J Radiat Oncol Biol Phys, 2006,66:748-753. 被引量:1
  • 3Cheung PC, Sixel KE, Tirona R, et al. Reproducibility of lung tumor position and reduction of lung mass within the planning target volume using active breathing control (ABC). Int J Radiat Oncol Biol Phys,2003 ,57 :1437-1442. 被引量:1
  • 4Wang L, Hayes S, Paskalev K, et al. Dosimetric comparison of stereotactic body radiotherapy using 4DCT and multiphase CT images for treatment planning of lung cancer: evaluation of the impact on daily dose coverage. Radiother Oncol, 2009,91:314-324. 被引量:1
  • 5Shih HA, Jiang SB, Aljarrah KM, et al. Internal target volume determined with expansion margins beyond composite gross tumor volume in three dimensional conformal radiotherapy for lung cancer. Int J Radiat Oncol Biol Phys,2004,60:613-622. 被引量:1
  • 6Seppenwoolde Y, Shirato H, Kitamura K, et al. Precise and real- time measurement of 3D tumor motion in lung during to breathing and heartbeat, measured during radiotherapy. Int J Radiat Oncol Biol Phys ,2002,53:822-834. 被引量:1
  • 7Nakamura M, Narita Y, Matsuo Y, et al. Geometrical differences in target volume between slow CT and 4DCT imaging in stereotactie body radiotherapy for lung tumors in the upper and middle lobe. Med Phy,2008,35:4142-4148. 被引量:1
  • 8Ezhil M, Vedam S, Baiter P, et ai. Determination of patient- specific internal gross tumor volumes for lung cancer using four- dimensional computed tomography. Radiat 0ncol,2009,4:1-14. 被引量:1
  • 9尚东平,李明焕,李建彬,尹勇,于金明,杜君.四维CT技术确定肺内孤立性病灶靶体积应用[J].中华放射肿瘤学杂志,2011,20(5):417-419. 被引量:12

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部