摘要
研究了多碱光电阴极光谱响应峰值位置移动技术。利用多碱光电阴极多信息量测控技术,可以控制光电阴极光谱响应峰值位置,以满足不同性能光电管光谱匹配的需要。对夜天光辐射以及一些材料的光谱反射,利用多信息量测控技术,可以将多碱光电阴极的光谱响应峰值移至0.8μm处。
The peak value position shifting technology for spectral response of multialkali photocathodes is studied. The peak value position of spectral response of multialkali photocathodes can be controlled to meet the needs of different spectral response characteristices of various photoemissives devices. For sounding reflectance of night sky and spectral reflection on some materials, the peak value position of spectral response of multialkali photocathodes can be moved to 0.8 μm by multi information measuring techniques.
出处
《光学学报》
EI
CAS
CSCD
北大核心
1998年第2期233-237,共5页
Acta Optica Sinica
关键词
多碱光电阴极
光谱响应
夜视仪器
峰值位置
multialkali photocathodes, spectral response, measure, night devices.