期刊文献+

血液中Cr、Cd、As、Tl和Pb的电感耦合等离子体质谱分析 被引量:20

Determination of Cr, Cd, As, Tl and Pb in Blood by Inductively Coupled Plasma Mass Spectrometry
下载PDF
导出
摘要 目的建立血液中Cr、Cd、As、Tl和Pb的电感耦合等离子体质谱(ICP-MS)分析方法。方法血液采用微波消解仪进行处理,以115In元素作内标,使用ICP-MS方法对血液中Cr、Cd、As、Tl和Pb进行分析。结果方法检出限为0.00001~0.00249μg/L,准确度为90.1%~110.7%,精密度为4.0%~7.9%。结论建立的方法准确、快速、线性范围宽、灵敏度高,适用于Cr、Cd、As、Tl和Pb中毒案件的检测。 Objective To establish an inductively coupled plasma mass spectrometry(ICP-MS) method for determination of Cr, Cd, As, Tl and Pb in blood. Methods The samples were digested by microwave digestion instrument. ICP-MS was applied to determine Cr, Cd, As, Tl and Pb in blood by using ^115In as an internal standard. Results The limits of detection were in the range of 0.000 01-0.002 49μg/L. The accuracy of the method ranged from 90.1% to 110.7% and the precision ranged from 4.0% to 7.9%. Conclusion The method is accurate and rapid with superior sensitivity and linear range. It could be used in the poisoning cases caused by Cr, Cd, As, Tl and Pb.
出处 《法医学杂志》 CAS CSCD 2009年第1期37-39,共3页 Journal of Forensic Medicine
基金 中央级科研院所社会公益研究资助项目(GY0602)
关键词 法医毒理学 电感耦合等离子体质谱法 血液 金属 forensic toxicology inductively coupled plasma mass spectrometry blood metals, heavy
  • 相关文献

参考文献9

  • 1王小如..电感耦合等离子体质谱应用实例[M],2005.
  • 2宋娟娥,梁月琴,于水.电感耦合等离子体质谱法测定人血浆中20种微量元素[J].分析化学,2007,35(3):423-426. 被引量:31
  • 3杨艳伟,丁亮,戚其平,姚孝元,刘建荣.全血中23种微量元素的微波消解电感耦合等离子体质谱测定法[J].环境与健康杂志,2003,20(4):240-241. 被引量:22
  • 4申治国,徐新云,张顺祥,张仁利,何雅青.ICP-AES和ICP-MS法测定血中微量元素[J].现代预防医学,2003,30(5):644-645. 被引量:13
  • 5Lehn SA, Warner KA, Huang M, et ol. Effect of an inductively coupled plasma mass spectrometry sampler interface on electron temperature, electron number density, gas-kinetic temperature and analyte emission intensity upstream in the plasma[J]. Spectrochimica Acta, Part B : Atomic Spectroscopy,2002,57( 11 ) : 1739-1751. 被引量:1
  • 6Karunasagar D, Arunachalam J. Determination of cadmium by inductively coupled plasma mass spectrometry-reduction of molybdenum oxide interferences by addition of acetonitrile[J]. Analytica Chimica Acta,2001, 441 (2) :291-296. 被引量:1
  • 7Elwaer N, Hintelmann H. Comparing the precision of selenium isotope ratio measurements using collision cell and sector field inductively coupled plasma mass spectrometry[J]. Talanta, 2008,75 ( 1 ) : 205-214. 被引量:1
  • 8Llorente I, Gomez M, Camara C. Improvement of selenium determination in water by inductively coupled plasma mass spectrometry through use of organic compounds as matrix modifiers[J]. Spectrochimica Acta Part B : Atomic Spectroscopy, 1997,52(12) : 1825-1838. 被引量:1
  • 9Lariviere D, Reiber KM, Evans RD, et al. Determination of ^210Pb at ultra-trace levels in water by ICPMS[J]. Analytica Chimica Acta,2005,549: 188-196. 被引量:1