期刊文献+

装配式轻钢结构临建房屋技术性能与应用研究 被引量:3

THE TECHNICAL PERFORMANCE AND APPLIED RESEARCH ON TEMPORARY LIGHT STEEL STRUCTURE ASSEMBLED HOUSING
原文传递
导出
摘要 青岛援建四川北川陈家坝地区震后过渡安置房采用装配式轻钢结构临建房屋。该临建房屋为冷弯薄壁型钢结构体系,桁架杆件之间采用无节点板直接焊接的连接形式,具有制作简单,自重轻,安装方便,可拆卸重复利用,施工周期短,结构受力可靠,抗震能力强等技术特点。针对这种连接形式研究了桁架杆件承载力及次应力的分布和影响。分析结果表明:援建的临建房屋结构具有足够的安全性能,采用无节点板连接的钢桁架,由于杆件几何偏心的影响,进行内力分析时应考虑次应力的不利影响。 Post-earthquake transitional housings which built in Chenjiaba District, Beichuan County, Sichuan Province aided by Qingdao are light steel structure assembled housings. For which cold-formed thin-wall steel structure system is used and jointless plates with direct welding connection are also used between truss members and are characterised by simple production, light weight, easy installation, convenient disassembly and reuse, short construction period, reliable structure force and strong seismic ability. It is analysed bearing capacity of truss members and the distribution and effect of the secondary stresses. The results show that transitional housing placements structure has adequate security. The adverse effects of secondary stress due to node geometric flaw to steel truss without node plate connections should be considered when internal force is analysed.
出处 《工业建筑》 CSCD 北大核心 2009年第1期52-55,共4页 Industrial Construction
关键词 轻钢结构临建房屋 冷弯薄壁型钢 次应力 节点连接 transitional housing with light steel structure cold-formed thin-wall steel secondary stress node connection
  • 相关文献

参考文献7

二级参考文献2

  • 1陈精一 蔡国中.电脑辅助工程设计ANSYS使用指南[M].北京:中国铁道出版社,2001.. 被引量:4
  • 2祝校华,余志祥.ANSYS高级工程有限元分析范例精选.北京:电子工业出版社,2004. 被引量:1

共引文献1286

同被引文献34

  • 1侯和涛,孙燕飞,刘玮龙.轻钢装配式住宅示范工程的设计与应用[J].建筑钢结构进展,2013,15(5):35-40. 被引量:13
  • 2童根树,吴光美.钢柱脚锚栓设计内力计算方法综述[J].建筑结构,2004,34(6):55-57. 被引量:21
  • 3GB50017-2003.钢结构设计规范[S].[S].,.. 被引量:2065
  • 4周长吉.现代温室工程[M].北京:化学工业出版社,2002.. 被引量:7
  • 5Takamatsu Tamai H.Non-slip-type restoring force characteristics of an exposed-type column base[J].Journal of Constructional Steel Research, 2005, 61(7): 942-961. 被引量:1
  • 6李黎明,王凯,牟在根.方钢管柱装配式柱脚试验研究[C]//第21届全国结构工程学术会议论文集第III册,沈阳,2012:60-65. 被引量:1
  • 7吴桂芳.柱脚锚栓的抗拉设计[C]// 第21届全国结构工程学术会议论文集第III册,沈阳,2012:134-138. 被引量:1
  • 8Ueda T, Kitipornchai S, Ling K.Experimental investigation of anchor bolts under shear[J].ASCE, Journal of Structural Engineering, 1988(4): 98-110. 被引量:1
  • 9Klingner R E, Mendonca J A.Shear capacity of short anchor bolts and welded studs: a literature review[J].ACI Journal,1982, 79(5): 339-349. 被引量:1
  • 10Li Xiao, Ding Min, Jiang Xiugen.Theoretical analysis of the sole plate of semi-rigid light steel column footings on the basis of Winkler model of elastic foundation beam[J].Advanced Materials Research, 2013, 660: 105-110. 被引量:1

引证文献3

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部