期刊文献+

温度对超声波探头灵敏度的影响 被引量:3

The Influence of Temperature on Piezoelectric Effect of Ultrasonic Probe
下载PDF
导出
摘要 在恒温工作台上将标准试块加热,测试不同温度下,高温探头发射/接收超声波能力的变化,以研究温度对探头压电效应的影响。试验结果证明,高温使探头的压电效应减弱,探头发射和接收超声波的能力因此大幅降低甚至完全消失,从而制约了高温超声波检测技术的应用。 By heating the reference block on a constant temperature worktable, and testing the changes of the probe's capability of transmitting and receiving ultrasonic wave, this paper investigated that how the temperature influences probe's piezoelectric effect of the probe. The experimental results showed that high temperature weakened the piezoelectric effect, made the probe's capability of transmitting and receiving ultrasonic decreased even lost. So that the high temperature restricted the application of high temperature UT.
出处 《无损检测》 2009年第1期53-55,共3页 Nondestructive Testing
关键词 超声波检测 高温 探头 压电效应 Ultrasonic testing| High temperature Probe Piezoelectric effect
  • 相关文献

参考文献3

二级参考文献20

  • 1谢宝琛,王兆节,徐正江.斜探头K值随环境温度的变化[J].无损检测,1989,11(8):226-228. 被引量:7
  • 2高温横波探伤中温度梯度的影响[J].无损探伤,1986,(3). 被引量:2
  • 3RW尼柯尔斯.压力容器技术进展-2探伤与检验[M].北京:机械工业出版社,1994.. 被引量:1
  • 4.超声波探伤[M].北京:水利电力工业出版社,1985.. 被引量:1
  • 5.美国无损检测手册-超声卷[M].北京:北京图书出版公司,1996.. 被引量:1
  • 6章燕谋.锅炉与压力容器用钢[M].西安:交通大学出版社,1996.. 被引量:1
  • 7J克劳特克洛默 H·克劳特克洛默著 李靖等译.超声检测技术[M].广东:广东科技出版社,1984.. 被引量:3
  • 8Lynnworth, L.,Use of Ultrasonics for High Temperature Measurments Materids Evaluation[J],1969,27(3):60~66. 被引量:1
  • 9Silber, F., and O.Ganglbauer. Ultrasonic Testing of Hot welds, NDT International[J],1970,3(6):471~476. 被引量:1
  • 10Canella, G. and F. Monti,Ultrasonic Inspection of Hot Thick Steel Products NDT International[J], 1980,13(61):10~14. 被引量:1

共引文献36